Calibration and Application of an X-ray Image Intensifier/ Charge-Coupled Device Detector for Monochromatic Macromolecular Crystallography

Abstract: Charge-coupled device (CCD)-based X-ray detectors allow data to be collected much more quickly (--,10 times) than with current on-line imaging-plate systems. At the ESRF, X-ray image intensifier/CCD detector systems have been developed. These have great potential as fast read-out detectors for macromolecular and other forms of crystallography. They are relatively large sensitive X-ray detectors but have two inherent weaknesses: convex detection surfaces leading to spatial distortion and non-uniformity of inten… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
50
0
1

Year Published

2012
2012
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 64 publications
(52 citation statements)
references
References 10 publications
(13 reference statements)
0
50
0
1
Order By: Relevance
“…Buffer scattering was recorded before each sample scattering and then subtracted from the corresponding sample scattering. The integration of SAXS patterns was performed using Fit2D software (41) and data analysis using GNOM (42). Low resolution envelopes of each construction were calculated from the experimental SAXS data using ab initio procedure implemented in the DAMMIN program (43).…”
Section: Myosins V (Myovs)mentioning
confidence: 99%
“…Buffer scattering was recorded before each sample scattering and then subtracted from the corresponding sample scattering. The integration of SAXS patterns was performed using Fit2D software (41) and data analysis using GNOM (42). Low resolution envelopes of each construction were calculated from the experimental SAXS data using ab initio procedure implemented in the DAMMIN program (43).…”
Section: Myosins V (Myovs)mentioning
confidence: 99%
“…The remaining three B8 complexes were collected at BL4 (ESRF) (~ = 0.76 A) using an X-ray Image Intensifier Charged Couple Device (XRII)/ CCD Detector [32]. Data from the XRII/CCD Detector were first corrected for spatial distortion and non-uniformity of response over the detector system [33,34]. All diffraction data were autoindexed, integrated and corrected for Lorentz and polarization effects with the program DENZO [35] followed by scaling and merging in SCA-LEPACK [35].…”
Section: Diffraction Measurements and Data Processingmentioning
confidence: 99%
“…The integration of SAXS patterns was performed using Fit2D (26). Data were analyzed using the program GNOM (27).…”
Section: Methodsmentioning
confidence: 99%