2021
DOI: 10.1002/adhm.202001748
|View full text |Cite
|
Sign up to set email alerts
|

Blood‐Compatible Materials: Vascular Endothelium‐Mimetic Surfaces that Mitigate Multiple Cell‐Material Interactions

Abstract: When flowing whole blood contacts medical device surfaces, the most common blood–material interactions result in coagulation, inflammation, and infection. Many new blood‐contacting biomaterials have been proposed based on strategies that address just one of these common modes of failure. This study proposes to mitigate unfavorable biological reactions that occur with blood‐contacting medical devices by designing multifunctional surfaces, with features optimized to meet multiple performance criteria. These mult… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
20
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 7 publications
(21 citation statements)
references
References 66 publications
1
20
0
Order By: Relevance
“…Polyelectrolyte complex nanoparticles (PCNs) were prepared as previously described. ,,, Briefly, CHI (1 mg/mL), HEP (1.5 mg/mL), and CS (2.8 mg/mL) solutions were prepared in an acetate buffer solution (0.2 M sodium acetate and acetic acid at pH 5.0). Solutions were filtered using 0.22 μm PDVF syringe filters.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Polyelectrolyte complex nanoparticles (PCNs) were prepared as previously described. ,,, Briefly, CHI (1 mg/mL), HEP (1.5 mg/mL), and CS (2.8 mg/mL) solutions were prepared in an acetate buffer solution (0.2 M sodium acetate and acetic acid at pH 5.0). Solutions were filtered using 0.22 μm PDVF syringe filters.…”
Section: Methodsmentioning
confidence: 99%
“…PEMs were prepared as previously described. , Briefly, chitosan (CHI) (1 mg/mL) and HA (0.5 mg/mL) solutions were prepared with acetate buffer (0.2 sodium acetate and acetic acid at pH 5.0). Solutions were stirred for at least 2 h at room temperature and were then filtered through 2.0 um PDVF syringe filters.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Additionally, the nitrosation process may disturb the surface layer of heparin and cause polysaccharides to disperse into solution. This physically changes the surface roughness and might further affect the coagulation cascade [47].…”
Section: Detection Of Chemical Modification By the Nitrosation Process Via Attenuated Total Reflectance-fourier Transform Infrared (Atr-fmentioning
confidence: 99%