2022
DOI: 10.1016/j.apsusc.2022.152663
|View full text |Cite
|
Sign up to set email alerts
|

Bifunctional ionic hyper-cross-linked polymers for CO2 capture and catalytic conversion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 50 publications
(15 citation statements)
references
References 45 publications
2
13
0
Order By: Relevance
“…Higher uptakes are found for DF8 with 73.28 cm 3 /g (3.26 mmol/g) of CO 2 adsorbed at a pressure around 1 bar while for DF2 the amount of CO 2 adsorbed is assessed at 57.40 cm 3 /g (2.55 mmol/g) around 1 bar. These values are comparable 23−25 or higher 3,12,22 with respect to CO 2 uptakes recorded for other hyper-cross-linked polymers (see also Table S1). If a ratio between the SSA BET and the amount of CO 2 adsorbed by the material is obtained it is seen that DF materials, particularly DF2, show a ratio lower with respect to many reported HCPs (see Table S1).…”
Section: ■ Results and Discussionsupporting
confidence: 78%
See 3 more Smart Citations
“…Higher uptakes are found for DF8 with 73.28 cm 3 /g (3.26 mmol/g) of CO 2 adsorbed at a pressure around 1 bar while for DF2 the amount of CO 2 adsorbed is assessed at 57.40 cm 3 /g (2.55 mmol/g) around 1 bar. These values are comparable 23−25 or higher 3,12,22 with respect to CO 2 uptakes recorded for other hyper-cross-linked polymers (see also Table S1). If a ratio between the SSA BET and the amount of CO 2 adsorbed by the material is obtained it is seen that DF materials, particularly DF2, show a ratio lower with respect to many reported HCPs (see Table S1).…”
Section: ■ Results and Discussionsupporting
confidence: 78%
“…bar. These values are comparable [23][24][25] or higher 3,12,22 with respect to CO2 uptakes recorded for other hypercrosslinked polymers (see also Table S1). If a ratio between the SSABET and the amount of CO2 adsorbed by the material is obtained it is seen that DF materials, particularly DF2, show a ratio lower with respect to many reported HCPs (see Table S1).…”
Section: Resultssupporting
confidence: 78%
See 2 more Smart Citations
“…A probable explanation for these drops is that the pores were partially blocked by the produced phosphonium-based ILs. 40 Fig. 4b shows that the pore-size distribution of PPh 2 PStD-PCoVPP-1 was mainly in the range of 3.8 nm to 32.36 nm.…”
Section: Preparation and Characterization Of The Bifunctional Porous ...mentioning
confidence: 93%