1934
DOI: 10.1007/bf01341392
|View full text |Cite
|
Sign up to set email alerts
|

�ber einen neuen Massenspektrographen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
77
0
1

Year Published

1996
1996
2011
2011

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 278 publications
(78 citation statements)
references
References 0 publications
0
77
0
1
Order By: Relevance
“…Since this procedure differs from the conventional analytic protocol in which noble gases are first purified and then released into a mass spectrometer at a single well-defined time, we describe it in more detail. The gas extraction, processing, and analysis system is composed of three sections in series: (a) a multi-sample furnace in which samples wrapped in Pt foil are connected across Pt leads and heated by stepped pulses of increasing electrical power; (b) a gas purification section equipped with Westinghouse @ WL and NP10 getters, a SAES @ metal appendage getter, and cryopumping on stainless steel (SS) and activated charcoal fingers at liquid N 2 temperature; and (c) a 3 .75 double-focusing Mattauch-Herzog geometry mass spectrometer equipped with pulse-counting detectors (Mattauch & Herzog 1934;Nier & Schlutter 1985). Gases evolved during a heating step in (a) are released directly into section (b) where they are exposed to the getters and cryopumped for one minute on the SS finger to reduce abundances of chemically active and condensable species.…”
Section: Totalsmentioning
confidence: 99%
“…Since this procedure differs from the conventional analytic protocol in which noble gases are first purified and then released into a mass spectrometer at a single well-defined time, we describe it in more detail. The gas extraction, processing, and analysis system is composed of three sections in series: (a) a multi-sample furnace in which samples wrapped in Pt foil are connected across Pt leads and heated by stepped pulses of increasing electrical power; (b) a gas purification section equipped with Westinghouse @ WL and NP10 getters, a SAES @ metal appendage getter, and cryopumping on stainless steel (SS) and activated charcoal fingers at liquid N 2 temperature; and (c) a 3 .75 double-focusing Mattauch-Herzog geometry mass spectrometer equipped with pulse-counting detectors (Mattauch & Herzog 1934;Nier & Schlutter 1985). Gases evolved during a heating step in (a) are released directly into section (b) where they are exposed to the getters and cryopumped for one minute on the SS finger to reduce abundances of chemically active and condensable species.…”
Section: Totalsmentioning
confidence: 99%
“…Electron ionization, which was the most practical approach at the time, limited analysis to volatile and semivolatile organics. Moreover, early mass spectrometers based on the magnetic sector technology of the 1940s and 1950s could achieve mass resolving power of 10,000 or higher but were inherently limited by slit-dependent resolution (1,2). Narrowing the slit increased resolving power but at the expense of reduced S/N.…”
Section: Infant Yearsmentioning
confidence: 99%
“…All data presented in this work are produced using a miniature MH-mass spectrometer [3,58], which is widely used in compact transportable MS and GC/MS products (IonCam). The instrument is shown in Figure 1 and its parameters are summarized in Table 1.…”
Section: Methodsmentioning
confidence: 99%