Benchmark of AC and DC Active Power Decoupling Circuits for Second-Order Harmonic Mitigation in Kilowatt-Scale Single-Phase Inverters

Abstract: Users may download and print one copy of any publication from the public portal for the purpose of private study or research.  You may not further distribute the material or use it for any profit-making activity or commercial gain.  You may freely distribute the URL identifying the publication in the public portal.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0
3

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 106 publications
(31 citation statements)
references
References 21 publications
(44 reference statements)
0
28
0
3
Order By: Relevance
“…Such low frequency component in the input current can effectively be mitigated in any closed-loop system as in [19]- [21]. Furthermore, the low frequency component in the dc-link voltage can be mitigated by means of decoupling circuits as discussed in [22].…”
Section: B Mathematical Derivationmentioning
confidence: 99%
“…Such low frequency component in the input current can effectively be mitigated in any closed-loop system as in [19]- [21]. Furthermore, the low frequency component in the dc-link voltage can be mitigated by means of decoupling circuits as discussed in [22].…”
Section: B Mathematical Derivationmentioning
confidence: 99%
“…The full-bridge converter here is operated with the bipolar sinusoidal pulse width modulation (SPWM), which helps reduce the level of leakage currents [6]. The ripple eliminator at the DC side, i.e., a boost-type DC/DC converter, is employed because of its better performance on the reduction of total capacitance and also on the efficiency, compared to AC decoupling methods [35]. This full-bridge system has the four main features of the proposed converter: 1) significantly-reduced leakage currents; 2) significantly-reduced total capacitance required; 3) low DC output ripples; 4) capability of bidirectional power flow without limitations on power factors.…”
Section: A a Full-bridge System For Comparisonmentioning
confidence: 99%
“…The V af is higher than the V + due to the boost operation of the ripple eliminator. The level of the voltage V a depends on the capacitors C a , C and also control strategies [35], which is normally set at similar level as the voltage V DC in the proposed converter if the total capacitance used is the same in the two converters. Based on the aforementioned analysis, it is found that the voltage stress of the Q 1 -Q 4 is higher than that of the Q 1f -Q 4f but is similar as that of the Q 5f and Q 6f .…”
Section: B Voltage Stress Of Switchesmentioning
confidence: 99%
“…The second harmonic current reduction methods are investigated even in kilowatt-scale converters. In [20] the benchmark study of active power decoupling (APD) for hi-power single-phase inverters was presented, where the feasibility and superiority of the identified solution for APD with the adaptive decoupling voltage control method were experimentally verified. The solar-powered aircraft or vehicle systems generate the specific requirements for used power electronics devices (PED).…”
Section: Introductionmentioning