2010
DOI: 10.1590/s0102-09352010000600011
|View full text |Cite
|
Sign up to set email alerts
|

Avaliação mecânica da placa de compósito de poli-hidroxibutirato e hidroxiapatita em modelos ósseos de gato

Abstract: RESUMOAvaliou-se mecanicamente o compósito de poli-hidroxibutirato 70% e hidroxiapatita 30% na forma de placas para fixação óssea. Foram utilizadas 15 placas do compósito com 60mm de comprimento por 10mm de largura e espessura variando de 3mm no centro a 5mm nas extremidades, com seis orifícios. As placas foram fixadas em um modelo acrílico de fêmur de gato, e o conjunto foi submetido aos testes de flexão com quatro pontos, compressão axial e torção, empregando-se como referência microplacas de aço ASTM-F138 2… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 14 publications
0
7
0
1
Order By: Relevance
“…The polyhydroxybutyrate/hydroxyapatite (PHB/HA) composite emerges as an alternative to the production of resorbable orthopedic implants. 6–10 This composite has both chemical and mechanical properties that are favorable for use as bone implants. 10 Its physical, chemical and structural properties are similar to the structure and chemical composition of bone.…”
mentioning
confidence: 99%
“…The polyhydroxybutyrate/hydroxyapatite (PHB/HA) composite emerges as an alternative to the production of resorbable orthopedic implants. 6–10 This composite has both chemical and mechanical properties that are favorable for use as bone implants. 10 Its physical, chemical and structural properties are similar to the structure and chemical composition of bone.…”
mentioning
confidence: 99%
“…However, Alves et al [25] mechanically evaluated the 70% polyhydroxybutyrate and 30% hydroxyapatite composite in the form of plate for bone fixation, and it was observed that the addition of HA in the polymer matrix caused reduction in the mechanical strength of the composites, because the particles acted as distributed defects in the organic matrix. 3.5 X-ray diffraction (XRD) Figure 9 shows the Bragg-Brentano profile of the samples of the polymer with addition of 3% HA.…”
Section: Scanning Electron Microscopy (Sem)mentioning
confidence: 99%
“…Between 50 and 200 °C, the loss of approximately 10% of the initial mass resulted from the physical degradation of smaller groups, evaporation of solvent molecules and volatile organic compounds from the sample [16][17][18][19][20][21][22][23][24][25][26] . Between 200 and 300 °C, the loss of 50% of the mass occurred.…”
Section: Differential Scanning Calorimetry (Dsc) and Thermogravimetrymentioning
confidence: 99%
See 1 more Smart Citation
“…Desde la década de 1970, el pericardio bovino ha sido uno de los materiales empleados para la fabricación de bioprótesis (Polak y Pitombo, 2011), el cual es tratado con glutaraldehído para eliminar células mesoteliales (Gauvin et al, 2013) y evitar el trasplante de proteínas o ADN en el receptor (Alves et al, 2010;Li et al, 2014). Sin embargo, se han reportado residuos citotóxicos que inducen la calcificación de las bioprótesis (Abolhoda et al, 1996).…”
Section: Introductionunclassified