1990
DOI: 10.1109/61.57986
|View full text |Cite
|
Sign up to set email alerts
|

Availability of corona cage for predicting radio interference generated from HVDC transmission line

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

1991
1991
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(9 citation statements)
references
References 5 publications
0
9
0
Order By: Relevance
“…The availability of the corona cage for predicting the radio interference and the audible noise generated from the HVDC transmission line was verified by Nakano and Sunaga [34,35] through experiments. It is based on the assumption that generation quantities of the radio interference, the audible noise and the corona current under different gap distances are the same by keeping the electric field on conductor surface the same in the presence of space charge, and the corona plasma region is neglected in calculating the electric field.…”
Section: Discussionmentioning
confidence: 99%
“…The availability of the corona cage for predicting the radio interference and the audible noise generated from the HVDC transmission line was verified by Nakano and Sunaga [34,35] through experiments. It is based on the assumption that generation quantities of the radio interference, the audible noise and the corona current under different gap distances are the same by keeping the electric field on conductor surface the same in the presence of space charge, and the corona plasma region is neglected in calculating the electric field.…”
Section: Discussionmentioning
confidence: 99%
“…Corona cage is an ideal tool to study the corona performance of the transmission lines. Its availability has been confirmed [2,3]. Put a corona cage in a manual environment room and test the corona performance of the line in the cage is a very economic way.…”
mentioning
confidence: 99%
“…A great number of EMI detections have been made over the past 50 years, primarily in the AM broadcast [1,7,8]. Some measurements have also been made in the TV band.…”
Section: Introductionmentioning
confidence: 99%
“…As transmission voltages of High-Voltage Alternating Current (HVAC) as well as HVDC transmission lines increase, corona discharge becomes a design factor, not only because of corona losses and their impact on efficiency of power transmission, but also due to the electromagnetic interference (EMI) caused to broadcast [1][2][3][4][5]. Moreover, the corona-generated ions produced by high-voltage transmission lines may affect health by enhancing exposure to aerosol pollutants [6].…”
Section: Introductionmentioning
confidence: 99%