Automated interictal source localisation based on high-density EEG

Abstract: To study the accuracy of automated interictal EEG source localisation based on high-density EEG, and to compare it to low-density EEG. Methods: Thirty patients operated for pharmacoresistant focal epilepsy were retrospectively examined. Twelve months after resective brain surgery, 18 were seizure-free or had 'auras' only, while 12 had persistence of disabling seizures. Presurgical 257-channel EEG lasting 3-20 h was down-sampled to 25, 40, and 204 channels for separate analyses. For each electrode setup, interi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
19
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(19 citation statements)
references
References 36 publications
(65 reference statements)
0
19
0
Order By: Relevance
“…EEG source localization based on recordings with a limited number of electrodes can be better integrated into the clinical setting and broaden the practical applications. sLORETA localization properties have been independently validated [ 45 ] and the accuracy has been demonstrated to be similar in high- and low-density EEG [ 46 , 47 ]. Therefore, we believe that there is a justification for reporting our results.…”
Section: Discussionmentioning
confidence: 99%
“…EEG source localization based on recordings with a limited number of electrodes can be better integrated into the clinical setting and broaden the practical applications. sLORETA localization properties have been independently validated [ 45 ] and the accuracy has been demonstrated to be similar in high- and low-density EEG [ 46 , 47 ]. Therefore, we believe that there is a justification for reporting our results.…”
Section: Discussionmentioning
confidence: 99%
“…Also, the high-density EEG with additional electrodes can improve the results of source reconstruction. However, the properties of sLORETA localization have been independently validated [ 25 ] with accuracy similar in high- and low-density EEG [ 40 , 41 ]. Therefore, we believe that our results are justified.…”
Section: Discussionmentioning
confidence: 99%
“…All patients underwent long term video-EEG (LTM) recording in the epilepsy monitoring unit, where at least one seizure was detected. LTM EEG was recorded using 40 scalp electrodes, in accordance with the 10-10 setting, by adding to the standard IFCN 25-channel electrodes [ 20 ] eight intermediate electrodes (FC1, FC2, FC5, FC6, CP1, CP2, CP5, CP6) and seven inferior electrodes (AF1, AF2, PO1, PO2, IO1, IO2, Iz) [ 16 ]. Subsequently, high density EEG (HD) was performed in 15 patients (median age: 29 years, range 12–61; 7 females).…”
Section: Methodsmentioning
confidence: 99%
“…The inverse solution method, the number of electrodes (low density, extended scalp array, high density or very high density), the signal (ictal or interictal) and the software used to perform ESI are all factors that have to be considered when performing ESI [ 7 , 13 , 14 , 15 , 16 , 17 , 18 ]. Therefore, several studies were conducted to explore differences between various inverse solutions [ 14 , 15 ], interictal and ictal source imaging [ 13 ], low and high density EEG [ 16 , 17 , 18 ] and different software [ 10 ]. However, in clinical practice, in spite of a standardized analysis protocol, ESI includes steps with subjective decisions about the individual patient by the analyser, i.e., the expert doing the ESI.…”
Section: Introductionmentioning
confidence: 99%