2018
DOI: 10.1016/j.heliyon.2018.e00669
|View full text |Cite
|
Sign up to set email alerts
|

Automated analysis of images for molecular quantification in immunohistochemistry

Abstract: The quantification of the expression of different molecules is a key question in both basic and applied sciences. While protein quantification through molecular techniques leads to the loss of spatial information and resolution, immunohistochemistry is usually associated with time-consuming image analysis and human bias. In addition, the scarce automatic software analysis is often proprietary and expensive and relies on a fixed threshold binarization. Here we describe and share a set of macros ready for automa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
44
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 54 publications
(47 citation statements)
references
References 32 publications
1
44
0
Order By: Relevance
“…Visualization and quantification of fluorescently labeled cells are important for studying human developmental biology . However, accurate analysis of fluorescent signals in images is often cofounded by autofluorescence and poor image segmentation .…”
Section: Resultsmentioning
confidence: 99%
“…Visualization and quantification of fluorescently labeled cells are important for studying human developmental biology . However, accurate analysis of fluorescent signals in images is often cofounded by autofluorescence and poor image segmentation .…”
Section: Resultsmentioning
confidence: 99%
“…On these planes, four small areas of the neuropil (300 μm 2 each) were selected for analysis, in order to avoid blood vessels and cell somata. Images were processed using different customized macros as previously described (Guirado, Carceller, Castillo‐Gómez, Castrén, & Nacher, ). In short, noise was reduced using a Gaussian blur filter and images were binarized, creating a mask containing the 2% brightest pixels; the outline of this mask was used in the original image to measure the number and fluorescence intensity of puncta.…”
Section: Methodsmentioning
confidence: 99%
“…Images were processed using different customized macros as previously described (Guirado, Carceller, Castillo-Gómez, Castrén, & Nacher, 2018).…”
Section: Analysis Of Immunoreactive Puncta In the Neuropilmentioning
confidence: 99%
“…The relative mean fluorescence intensity (MFI) for ALK5 immunofluorescence in the entire superficial dorsal horn, including 16 spinal cord sections from four rats (4 sections from each rat from each group) was measured using ImageJ software. 1,25 The fold change associated with the control group was set at 1.0 for quantification.…”
Section: Immunofluorescencementioning
confidence: 99%