2009
DOI: 10.1016/j.ijcard.2007.11.101
|View full text |Cite
|
Sign up to set email alerts
|

Atrial myocardial pathoelectrophysiology in adults with a secundum atrial septal defect is unaffected by closure of the defect. A study using high resolution signal-averaged orthogonal P-wave technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
11
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 23 publications
1
11
0
Order By: Relevance
“…The ASD closure technique did not affect the P wave in a comparison of different percutaneous techniques, or surgical repair and percutaneous techniques in previous studies 3,11. Javadzadegan et al3 suggested that in both percutaneous ASD closure and surgical treatment, the P-wave duration was decreased at six months’ follow up and this decrease was not related to the defect size.…”
Section: Discussionmentioning
confidence: 81%
See 2 more Smart Citations
“…The ASD closure technique did not affect the P wave in a comparison of different percutaneous techniques, or surgical repair and percutaneous techniques in previous studies 3,11. Javadzadegan et al3 suggested that in both percutaneous ASD closure and surgical treatment, the P-wave duration was decreased at six months’ follow up and this decrease was not related to the defect size.…”
Section: Discussionmentioning
confidence: 81%
“…By contrast, Thilen et al11 declared that increased P-wave duration did not decrease with surgical repair in older patients and it was not related to atrial dilatation. In haemodynamically significant ASD, the increase in P-wave duration may depend on regional damage of the atrial conduction pathways rather than atrial enlargement 12,13…”
Section: Discussionmentioning
confidence: 90%
See 1 more Smart Citation
“…Many papers have focused on this issue from different aspects. These aspects included the hemodynamic status 15 as well as electrocardiographic, 16,17 functional, [18][19][20][21][22] and volumetric reverse remodeling [23][24][25][26] ; none of which have correlated remodeling to MVP status.…”
Section: Discussionmentioning
confidence: 99%
“…A prolonged SAECG P-wave duration was also mentioned in septal atrial defect, especially in patients who experienced AF, not corrected after atrial septal defect closure, and it was demonstrated that atrial conduction disturbances occur early, requiring an early intervention to prevent the development of late AF ( Table 2) [47].…”
Section: P-wave Potentialsmentioning
confidence: 99%