2015
DOI: 10.1016/j.ijpharm.2015.09.018
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Raman spectroscopy as a fast and non-invasive method for total stratum corneum thickness determination of pig skin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
21
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 23 publications
(23 citation statements)
references
References 7 publications
2
21
0
Order By: Relevance
“…For example, for the isolated pig SC, a thickness of 11.90 ± 2.60 μm was determined. If compared with the investigations by Mahrhauser et al [34], other methods of measurement provide similar results. Prepared SC from pig ears showed a thickness of 11.15 ± 1.52 μm by Raman spectroscopy, with NIR densitometry measurements of 10.22 ± 2.64 and 10.91 ± 2.03 μm.…”
Section: Resultssupporting
confidence: 79%
“…For example, for the isolated pig SC, a thickness of 11.90 ± 2.60 μm was determined. If compared with the investigations by Mahrhauser et al [34], other methods of measurement provide similar results. Prepared SC from pig ears showed a thickness of 11.15 ± 1.52 μm by Raman spectroscopy, with NIR densitometry measurements of 10.22 ± 2.64 and 10.91 ± 2.03 μm.…”
Section: Resultssupporting
confidence: 79%
“…The reason can lie in cartilage detachment, which was shown to influence the measured SC thickness of approx. 25% and an increased occurrence of furrows, which was explained by the modified skin elasticity when the cartilage was removed .…”
Section: Discussionmentioning
confidence: 99%
“…Measurements were performed in the high wavenumber region (2,000-4,000 cm -1 ) with the 671 nm laser in 2 µm depth increments up to a depth of 40 µm at a signal collection time of 2 s per spectrum on 8 different locations of each area before and after hair removal. The SC thickness was calculated after constructing mean water concentration profiles [17][18][19]. The water content within the SC increases gradually from the outside to the inside until it reaches an almost constant value in the viable tissue [31].…”
Section: Crs: Sc Thicknessmentioning
confidence: 99%
“…Attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy was employed to investigate the effect of hair removal on SC constituents such as lipid matrix and proteins [15,16]. The SC thickness was determined by confocal Raman spectroscopy (CRS) [17][18][19] before and after hair removal. Finally, the effect of all hair removal methods on the skin permeation and skin penetration of the hydrophilic model permeant fluorescein sodium was investigated using Franz-type diffusion cells and in vitro tape stripping studies.…”
Section: Introductionmentioning
confidence: 99%