2020
DOI: 10.1002/acm2.12843
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of biological dosimetric margin for stereotactic body radiation therapy

Abstract: Purpose: To develop a novel biological dosimetric margin (BDM) and to create a biological conversion factor (BCF) that compensates for the difference between physical dosimetric margin (PDM) and BDM, which provides a novel scheme of a direct estimation of the BDM from the physical dose (PD) distribution.Methods: The offset to isocenter was applied in 1-mm steps along left-right (LR), anterior-posterior (AP), and cranio-caudal (CC) directions for 10 treatment plans of lung stereotactic body radiation therapy (S… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 36 publications
0
9
0
Order By: Relevance
“…The process for calculating the PDM and BDM was proposed in our previous study, as shown in Fig. 2 [ 4 ]. The treatment planning system used was RayStation (RaySearch, Sweden).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The process for calculating the PDM and BDM was proposed in our previous study, as shown in Fig. 2 [ 4 ]. The treatment planning system used was RayStation (RaySearch, Sweden).…”
Section: Methodsmentioning
confidence: 99%
“…Figure 3 illustrates the DM and treated volume (TV) proposed in a previous study [ 4 ]. Then, the isocenter was shifted from −20 to 20 mm in 1-mm steps along the LR, AP and CC directions in RayStation (step 2).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…These scenarios include a no setup error scenario, endpoint setup error scenario, and intermediate setup error scenario in the right‐left, inferior‐superior, and posterior‐anterior directions. The setup error, which was assumed to occur within the PTV margin, was determined to be the scenario 20 . Namely, the CTV dose with the setup error in the PTV‐based plan, which was used for the prescribed dose for the robust plan, was evaluated.…”
Section: Methodsmentioning
confidence: 99%
“…The setup error, which was assumed to occur within the PTV margin, was determined to be the scenario. 20 Namely, the CTV dose with the setup error in the PTV-based plan, which was used for the prescribed dose for the robust plan, was evaluated. The dose distribution in the moving coordinates of the PTVbased plan determined the dose constraint in the robust plan.…”
Section: Robust Planmentioning
confidence: 99%