2022
DOI: 10.1039/d1cp05445g
|View full text |Cite
|
Sign up to set email alerts
|

Application of W-band19F electron nuclear double resonance (ENDOR) spectroscopy to distance measurement using a trityl spin probe and a fluorine label

Abstract: Recently, Marina Bennati and coworkers (Angew. Chemie - Int. Ed., 2020, 59, 373–379., A. J. Magn. Reson., 2021, 333, 107091) proposed to use electron nuclear double resonance (ENDOR) spectroscopy in...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
59
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(61 citation statements)
references
References 67 publications
2
59
0
Order By: Relevance
“…6b are also partially suppressed and do not resolve the T > feature as would be expected for a single distance associated with a purely through-space dipolar coupling, again pointing to a significant isotropic contribution to the hyperfine interaction. This parallels the problems encountered by the authors of the recent publication on 19 F-ENDOR with a trityl radical paramagnetic spin tag, 21 which required more complicated computational modelling to validate the observed splittings. Whether interactions other than conjugation contribute to the splitting observed in the 19 F-ENDOR spectrum of the Gd 3+ - 19 F ruler is open to further investigation.…”
Section: F-endor Distance Measurementsmentioning
confidence: 62%
See 3 more Smart Citations
“…6b are also partially suppressed and do not resolve the T > feature as would be expected for a single distance associated with a purely through-space dipolar coupling, again pointing to a significant isotropic contribution to the hyperfine interaction. This parallels the problems encountered by the authors of the recent publication on 19 F-ENDOR with a trityl radical paramagnetic spin tag, 21 which required more complicated computational modelling to validate the observed splittings. Whether interactions other than conjugation contribute to the splitting observed in the 19 F-ENDOR spectrum of the Gd 3+ - 19 F ruler is open to further investigation.…”
Section: F-endor Distance Measurementsmentioning
confidence: 62%
“…To date, reliable 19 F-ENDOR distance measurements with trityl tags have only been achieved in the range of 8-12 Å with model compounds. 21 As trityl radicals are large and feature significant delocalization of the spin density, this introduces considerable uncertainty into the distance measurement, in particular if the trityl radical is attached to the target molecule via a flexible tether. Furthermore, for a tether containing conjugated linkers, a significant isotropic (fermi contact) hyperfine interaction at inter-spin distances shorter than about 8 Å is observed, 21 which complicates distance determination.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…This means, that small hyperfine couplings may be investigated by the choice of very long preparation intervals (up to 4 µs). [14,60] The limiting factor for the choice of τ is however the phase memory time of the investigated PC, as the overall ENDOR sensitivity S ENDOR is a product of the ENDOR efficiency and the echo intensity determined by relaxation:…”
Section: Endormentioning
confidence: 99%