2021
DOI: 10.1016/j.conbuildmat.2020.121008
|View full text |Cite
|
Sign up to set email alerts
|

Application of three self-developed ECT sensors for monitoring the moisture content in sand and mortar

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 43 publications
(10 citation statements)
references
References 36 publications
0
10
0
Order By: Relevance
“…In practical engineering applications, the structure may be in different saturated states. At this time, non-destructive testing moisture content testing can be used to measure the actual moisture content of the structure [ 29 , 30 , 31 ]. An approximate evaluation of fracture properties at low-temperature conditions with different moisture content forms the basis of this study.…”
Section: Methodsmentioning
confidence: 99%
“…In practical engineering applications, the structure may be in different saturated states. At this time, non-destructive testing moisture content testing can be used to measure the actual moisture content of the structure [ 29 , 30 , 31 ]. An approximate evaluation of fracture properties at low-temperature conditions with different moisture content forms the basis of this study.…”
Section: Methodsmentioning
confidence: 99%
“…The workability of concrete is defined in ASTM C 125 as the property that determines the effort required to manipulate freshly mixed concrete with a minimum loss of uniformity. The importance of workability in concrete technology is apparent [50]. It is one of the key properties that must be satisfied.…”
Section: Prepared With Electric-activated Watermentioning
confidence: 99%
“…Sensors 2021, 21, 7170 3 of 16 both stationary and dynamic measurements has been proven in several studies [22][23][24][25].…”
Section: Microwave Drying Processmentioning
confidence: 99%
“…However, these guard electrodes were not involved in the measurement procedure. The polymer foam 2D cross-section had a rectangular domain with a width of 49.3 cm, which dictated a wide rectangular shape for the ECT sensor structure, while most developed ECT sensors are round [25][26][27]. This unusual structure imposed a considerable distance between non-neighboring electrodes, resulting in a weak measurement signal.…”
Section: Electrical Capacitance Tomographymentioning
confidence: 99%
See 1 more Smart Citation