Applicability of electroanalysis for monitoring oxalic acid (OA) concentration during its electrochemical oxidation

Abstract: In the present paper, differential pulse voltammetry (DPV) techniques has been studied for monitoring of the concentration of oxalic acid (OA) during its electrochemical oxidation (EO) in acidic media at BDD anode applying a current of 60 mA cm 2 . Glassy carbon has been used for DPV measurements using two analytical procedures: calibration curves (DPVCC) and standard addition method (DPVSAM). DPV analyses have compared with classic titration method and HPLC achieving a good fit, confidence intervals and limits Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 24 publications
0
4
0
Order By: Relevance
“…Nowadays, the development of electrochemical sensing tools for various applications is receiving great attention [ 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 ]. Due to their inherent specificity, rapid measurement procedures, high accuracy, high sensitivity and simplicity of preparation, these measuring devices allow monitoring of different species in a satisfactory way.…”
Section: Introductionmentioning
confidence: 99%
“…Nowadays, the development of electrochemical sensing tools for various applications is receiving great attention [ 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 ]. Due to their inherent specificity, rapid measurement procedures, high accuracy, high sensitivity and simplicity of preparation, these measuring devices allow monitoring of different species in a satisfactory way.…”
Section: Introductionmentioning
confidence: 99%
“…limit of detection, LOD , was estimated by using the method based on the standard deviation of regression 42: …”
Section: Resultsmentioning
confidence: 99%
“…Anodic oxidation uses electrons under mild operating conditions, and the process is amenable to automatic control. Previous studies on anodic oxidation of OA have focused on the effect of the anode material on the rate of OA demineralization. Little work , has been done on the role of cell design in OA oxidation.…”
Section: Introductionmentioning
confidence: 99%