2021
DOI: 10.1007/s00106-021-00994-6
|View full text |Cite
|
Sign up to set email alerts
|

Ankopplung aktiver Mittelohrimplantate – biomechanische Aspekte

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
10
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(12 citation statements)
references
References 34 publications
1
10
0
1
Order By: Relevance
“…Right, The amplitude differences of the transfer function of the SP coupler with reference to the LP coupler are depicted compared to current literature data. The data of Bornitz (Bornitz et al 2010; Bornitz 2011; Bornitz et al 2021) have been generated by means of a finite-element model, all other data (Mlynski et al 2015b; Schraven et al 2016b; Raphael 2021) have been obtained from human TB experiments. The recent literature displays a high level of inhomogeneity.…”
Section: Resultsmentioning
confidence: 99%
“…Right, The amplitude differences of the transfer function of the SP coupler with reference to the LP coupler are depicted compared to current literature data. The data of Bornitz (Bornitz et al 2010; Bornitz 2011; Bornitz et al 2021) have been generated by means of a finite-element model, all other data (Mlynski et al 2015b; Schraven et al 2016b; Raphael 2021) have been obtained from human TB experiments. The recent literature displays a high level of inhomogeneity.…”
Section: Resultsmentioning
confidence: 99%
“…Based on the knowledge gained from LDV (laser doppler vibrometry) measurements of the temporal bone and simulated calculations regarding an optimal coupling of the FMT it is easy to understand the wish for a measurement method for intraoperative evaluation of the coupling efficiency 128 129 130 131 .…”
Section: Resultsmentioning
confidence: 99%
“…Comparison between acoustic stimulation and electromechanical stimulation by an FMT has only been performed in experimental studies using Laser-Doppler vibrometry so far. These studies provided objective evidence that acoustic stimulation is mechanically different from electromechanical stimulation by the VSB (9,10). However, normative data on the characteristics of VSB evoked ABRs as a new objective method were not available in the literature so far.…”
Section: Discussionmentioning
confidence: 99%
“…Thus, there is a risk of ineffective Abbreviations: AMEI, active middle ear implant; VSB, Vibrant Soundbridge; FMT, floating mass transducer; LP, long process (of the incus); SP, short process (of the incus); OW, oval window; RW, round window; VIB, vibrogram (thresholds); BC, bone conduction (thresholds); ASSR, auditory steady state response; CAP, compound action potential; ABR, auditory brainstem response; 3PTA coupling , pure tone average of coupling efficiency at 1, 2, and 4 kHz; AC, air conduction; 4PTA AC , pure tone average of air conduction thresholds at 0.5, 1, 2, and 4 kHz; 4PTA BC , pure tone average of bone conduction thresholds at 0.5, 1, 2, and 4 kHz; 4PTA VIB, pure tone average of vibrogram conduction thresholds at 0.5, 1, 2, and 4 kHz; L ABR, VSB evoked ABR thresholds; SD, standard deviation. movements with FMT resulting in a reduction of the transfer function (9). However, this was not visible in experimental Laser-Doppler vibrometry measurements with the SP-Coupler (5).…”
Section: Introductionmentioning
confidence: 90%
See 1 more Smart Citation