2016
DOI: 10.1016/j.jchromb.2016.06.048
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of antibody-drug conjugates by comprehensive on-line two-dimensional hydrophobic interaction chromatography x reversed phase liquid chromatography hyphenated to high resolution mass spectrometry. I − Optimization of separation conditions

Abstract: Antibody-drug-conjugates (ADCs) manufacturing leads to a mixture of species which needs to be characterized during development and for further quality control. The coupling of on-line HIC x RPLC to high resolution mass spectrometry can be considered as a very efficient analytical method, providing extensive information on ADC sample, within a reduced time scale. Our intention in this first paper is to present the approach used to rationally optimize the numerous conditions that can affect the quality of the 2D… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
44
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 57 publications
(48 citation statements)
references
References 26 publications
2
44
0
Order By: Relevance
“…An on-line HIC x RPLC-MS method has recently been reported for the thorough characterization of brentuximab vedotin [71,72]. The purpose was to get relevant information on both drug loaded profile and structural information on positional isomers of each DAR of the cysteine-linked commercial ADC.…”
Section: Multidimensional Separationmentioning
confidence: 99%
“…An on-line HIC x RPLC-MS method has recently been reported for the thorough characterization of brentuximab vedotin [71,72]. The purpose was to get relevant information on both drug loaded profile and structural information on positional isomers of each DAR of the cysteine-linked commercial ADC.…”
Section: Multidimensional Separationmentioning
confidence: 99%
“…HIC has only recently come back into fashion and there are few examples of its use in LC × LC. Heinisch et al used HIC × RPLC-MS for separating antibody-drug conjugates[145,146].…”
mentioning
confidence: 99%
“…In this context, several contributions have arisen in recent years, in response to this analytical demand, using heart-cutting, 137 multiple heart-cutting, 138 and comprehensive 2D-LC. 139 HIC × RPLC-HRMS was performed by Sarrut et al 139 Recently, the thorough and simultaneous characterization of both small and large molecules (drug payloads decorating mAbs in ADC formats) has also stimulated interest in the applications of 2D-LC. 136,137,139 As practical examples, Venkatramani et al 141 coworkers, 144 by analyzing several commercial mAbs and ADCs.…”
Section: Analysis Of Protein Biopharmaceuticals and Conjugatesmentioning
confidence: 99%
“…139 HIC × RPLC-HRMS was performed by Sarrut et al 139 Recently, the thorough and simultaneous characterization of both small and large molecules (drug payloads decorating mAbs in ADC formats) has also stimulated interest in the applications of 2D-LC. 136,137,139 As practical examples, Venkatramani et al 141 coworkers, 144 by analyzing several commercial mAbs and ADCs. It was found that the UHP-SEC columns were equivalent in terms of mAb characterization performance, since the average resolution for each column was between 1.9 -2.1 for the monomer and dimer forms of 10 different commercial mAbs.…”
Section: Analysis Of Protein Biopharmaceuticals and Conjugatesmentioning
confidence: 99%