2014
DOI: 10.1109/tie.2013.2281153
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and Design of Grid-Connected Photovoltaic Systems With Multiple-Integrated Converters and a Pseudo-DC-Link Inverter

Abstract: An architecture of multiple-integrated converter modules sharing an unfolding full-bridge inverter with a pseudo DC-link (MIP) is proposed for grid-connected photovoltaic (PV) systems in this paper. The proposed configuration can improve the power conversion, the control circuit complexity and the cost competitiveness. The proposed MIP is composed of distributed flyback dc-dc converters (DFC) and an unfolding full bridge inverter with an ac filter. The DFCs can eliminate the shading effect by using the individ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
33
0
2

Year Published

2014
2014
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 65 publications
(36 citation statements)
references
References 32 publications
(39 reference statements)
1
33
0
2
Order By: Relevance
“…Photovoltaic systems used for the solar energy conversion into electricity are constantly improved in the hardware and software [2][3]. One of the basic elements of the photovoltaic system is an inverter that is used to convert DC current and voltage obtained from photovoltaic cells to AC current and voltage with specified parameters.…”
Section: Introductionmentioning
confidence: 99%
“…Photovoltaic systems used for the solar energy conversion into electricity are constantly improved in the hardware and software [2][3]. One of the basic elements of the photovoltaic system is an inverter that is used to convert DC current and voltage obtained from photovoltaic cells to AC current and voltage with specified parameters.…”
Section: Introductionmentioning
confidence: 99%
“…An FC topology is used by Ye Zhao et al [68], to analyse the PV system fault. A distributed FC with tracking control is presented in [77] to reduce the losses due to shading.…”
Section: Flyback Convertermentioning
confidence: 99%
“…Due to the existence of a non-minimum phase (NMP) zero [8] and system dynamic issue [9] in CCM, the topology has instead been designed to operate in DCM. In exchange for simple dynamic, there exist several drawbacks to complicate the topology in order to make DCM practical.…”
Section: Introductionmentioning
confidence: 99%
“…The control problem for CCM, however, has recently been overcome by using a simple analogue controller [8,12] for the current controller. Another method is sampling the output from grid side filter instead [9], making it possible to control the system using digital controller.…”
Section: Introductionmentioning
confidence: 99%