2016
DOI: 10.1111/jopr.12437
|View full text |Cite
|
Sign up to set email alerts
|

An In Vitro Study of Condylar Displacement Caused by Interocclusal Records: Influence of Recording Material, Storage Time, and Recording Technique

Abstract: Based on the results, the vertical displacement of the condyle caused by the interocclusal records was higher than the lateral or the anteroposterior displacement. Elastomers caused statistically significantly less condylar displacement than waxes or uncorrected composite resin. Corrected LuxaBite records with Aluwax showed significantly less condylar displacement than all other materials.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 16 publications
0
4
0
Order By: Relevance
“…Studies on the accuracy of CR interocclusal recording materials provided insight in responding to focus question 2. [42][43][44][45][46][47][48][49][50][51][52][53][54][55][56][57][58][59] Assif et al 42 measured changes in vertical dimension using an electromechanical device in a study on 20 patients with a double wafer of base wax, wafer of base wax coated with zinc oxide-eugenol (ZOE) paste, acrylic resin, and polyether (PE) interocclusal recording material. PE was the most accurate among the four materials with a vertical discrepancy of 20 to 30 micrometers.…”
Section: Focus Question 2: What Effect Do Different Recording Materiamentioning
confidence: 99%
See 2 more Smart Citations
“…Studies on the accuracy of CR interocclusal recording materials provided insight in responding to focus question 2. [42][43][44][45][46][47][48][49][50][51][52][53][54][55][56][57][58][59] Assif et al 42 measured changes in vertical dimension using an electromechanical device in a study on 20 patients with a double wafer of base wax, wafer of base wax coated with zinc oxide-eugenol (ZOE) paste, acrylic resin, and polyether (PE) interocclusal recording material. PE was the most accurate among the four materials with a vertical discrepancy of 20 to 30 micrometers.…”
Section: Focus Question 2: What Effect Do Different Recording Materiamentioning
confidence: 99%
“…When limited to SRs, RCT's and Meta‐Analysis, and Clinical Trials among all search terms, 127 articles were selected for further analysis. Studies on the accuracy of CR interocclusal recording materials provided insight in responding to focus question 2 42–59 …”
Section: Focus Question 2: What Effect Do Different Recording Materiamentioning
confidence: 99%
See 1 more Smart Citation
“…Unfortunately, limited evidence and consensus exists to drive such procedures. To clarify the impact of materials on registration procedures, Ghazal et al 224 evaluated articulator condylar element displacements related to various interocclusal recording materials, record storage time, and the interocclusal recording technique used on the condylar element displacements.…”
mentioning
confidence: 99%