2020
DOI: 10.11591/ijece.v10i2.pp1169-1178
|View full text |Cite
|
Sign up to set email alerts
|

Abstract: In this paper, a new closed loop hybrid phase shift control is proposed for dual active bridge (DAB) converter with variable input voltage. The extended phase shift (EPS) control is applied when load gets heavy enough and the secondary side phase shift angle decreases to zero. When this modified DAB converter operates at light loads, the triple phase shift (TPS) modulation method is applied, and the added control freedom is the secondary phase shift angle between the two-secondary side switching legs. The hybr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
5

Relationship

4
1

Authors

Journals

citations
Cited by 6 publications
(12 citation statements)
references
References 26 publications
(26 reference statements)
0
12
0
Order By: Relevance
“…Also, in case of adjustment of the active filter on-side, it is very difficult to chose and tune the parameters of regulators if the real parameters of the power system differ from those designed. This fact has been proven during our experimental research experience [7,8]. The above-mentioned facts illustrate a very important, serious, and actual problem of the theory and methodology of structural and parametric synthesis of electrical complexes for power quality improvement on the basis of active and passive filters [43].…”
Section: Discussionmentioning
confidence: 59%
See 4 more Smart Citations
“…Also, in case of adjustment of the active filter on-side, it is very difficult to chose and tune the parameters of regulators if the real parameters of the power system differ from those designed. This fact has been proven during our experimental research experience [7,8]. The above-mentioned facts illustrate a very important, serious, and actual problem of the theory and methodology of structural and parametric synthesis of electrical complexes for power quality improvement on the basis of active and passive filters [43].…”
Section: Discussionmentioning
confidence: 59%
“…The first stage is the selection of character control ways from all plenty of the existing methods and theories for the further research. According to the results of numerous theoretical and experimental studies [7,8,[21][22][23][24][25][26], the ways developed for the determination and correction of power quality indicators for shunt active filter control may be divided into three main groups [27][28][29][30]:  Ways based on discrete (DFT) and fast Fourier (FFT) transformations [31][32][33][34][35].  Ways that extract the reference values of current or voltage using the theories and methods of current physical components (CPC) [22,23,36].…”
Section: The First Stagementioning
confidence: 99%
See 3 more Smart Citations