2011
DOI: 10.1016/j.aca.2011.06.014
|View full text |Cite
|
Sign up to set email alerts
|

An amperometric biosensor based on acetylcholinesterase immobilized onto iron oxide nanoparticles/multi-walled carbon nanotubes modified gold electrode for measurement of organophosphorus insecticides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
67
0
1

Year Published

2012
2012
2019
2019

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 179 publications
(74 citation statements)
references
References 44 publications
(39 reference statements)
2
67
0
1
Order By: Relevance
“…After storage for 70 days, the enzyme electrode maintained 50% of its first current response, which is better than previously reported electrodes. [17,18] …”
Section: Storage Stability Of Enzyme Electrodementioning
confidence: 99%
“…After storage for 70 days, the enzyme electrode maintained 50% of its first current response, which is better than previously reported electrodes. [17,18] …”
Section: Storage Stability Of Enzyme Electrodementioning
confidence: 99%
“…For PDDA-MWCNTs-GR/GCE (curve d), the Rct was 50 Ω, further decreased compared with curve b and curve c. The reason might be that the nano-hybrid of MWCNTs and GR could significantly reduce the aggregation and stacking between MWCNTs or GR, which resulted in enhanced surface area and wide porous structure of PDDA-MWCNTs-GR hybrid. When AChE was immobilized onto the surface of PDDA-MWCNTs-GR/GCE (curve e), the Rct remarkably increased to 1100 Ω due to the increase of the thickness of the interface, which insulated the conductive support and reduced the electron transfer between anionic [Fe(CN) 6 ] 3−/4− and GCE [46][47][48]. Figure 4(A) showed the cyclic voltammograms (CVs) of different fabricated electrodes in absence and presence of ATCl in pH 7.0 PBS.…”
Section: Electrochemical Impedance Analysismentioning
confidence: 99%
“…The detection limits and linear ranges obtained in this work were similar to, or better than, many reported in the literature using other sensors. 10,12,[30][31][32][33][34][35][36][37][38][39][40][41][42][43] This can be attributed to the efficiency of electron transfer between the CoTSPc/CNT/OMIM[BF4]/AChE biosensor and TCh, due to the catalytic effect of the CoTSPc/CNT/OMIM[BF4] composite. In addition, the reaction occurring at the CoTSPc/ CNT/OMIM[BF4]/AChE biosensor very quickly reached a dynamic equilibrium after each addition of the analyte, with a response time of less than 1 s for the signal to reach 100%.…”
Section: Study Of the Incubation Time Of The Cotspc/cnt/omim[bf4]/ Acmentioning
confidence: 99%