2017
DOI: 10.1186/s41601-017-0053-1
|View full text |Cite
|
Sign up to set email alerts
|

An adaptive supervised wide-area backup protection scheme for transmission lines protection

Abstract: Maloperation of conventional relays is becoming prevalent due to ever increase in complexity of conventional power grids. They are dominant during power system contingencies like power swing, load encroachment, voltage instability, unbalanced loading, etc. In these situations, adaptive supervised wide-area backup protection (ASWABP) plays a major role in enhancing the power system reliability. A balance between security and dependability of protection is essential to maintain the reliability. This paper propos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 33 publications
0
4
0
Order By: Relevance
“…Also, adaptive techniques based on various parameters to upgrade the security of protection of relay operation are found in the literature. Mallikarjuna et al proposed multi-phasor measurement units (MPMU) based adaptive supervised wide-area backup protection (ASWABP) scheme that can work adequately during faults besides the contingencies of the power system [11]. Jin and Sidhu [12] Avinash et al [13] Azari [14] Dubey et al [15] Khodaparast and Khederzadeh [16].…”
Section: Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, adaptive techniques based on various parameters to upgrade the security of protection of relay operation are found in the literature. Mallikarjuna et al proposed multi-phasor measurement units (MPMU) based adaptive supervised wide-area backup protection (ASWABP) scheme that can work adequately during faults besides the contingencies of the power system [11]. Jin and Sidhu [12] Avinash et al [13] Azari [14] Dubey et al [15] Khodaparast and Khederzadeh [16].…”
Section: Literature Reviewmentioning
confidence: 99%
“…But the models were tested with the different test sample collected during the time duration 1 to 1.5s (for load increase by 500 MW at 4th bus at 1s). This was nothing but a power swing condition (in the neighbouring line [4][5][6][7][8][9][10][11][12][13][14]. Offline techniques may fail to predict the condition because it was not trained for that pattern.…”
Section: 231event 1: Addition Of Loadmentioning
confidence: 99%
“…is was the rst time that the concept of widearea protection was introduced to relay protection, emphasizing the use of wide-area information to improve the performance of the support system. Mallikarjuna et al [8] proposed a multiphase measurement unit (MPMU) based on the ASWABP scheme to improve the safety and stability of the power system. is approach allows monitoring of standby security using a wide range as in conventional range security.…”
Section: Introductionmentioning
confidence: 99%
“…Such backup system plays a crucial role during power grid fault conditions and protection system breakdowns [1][2][3][4][5]. Hence, such methodologies are gaining much research attraction in recent years [6][7][8][9][10][11].…”
Section: Introductionmentioning
confidence: 99%