An actionable annotation scoring framework for gas chromatography-high-resolution mass spectrometry

Abstract: Omics-based technologies have enabled comprehensive characterization of our exposure to environmental chemicals (chemical exposome) as well as assessment of the corresponding biological responses at the molecular level. Systematically measuring exposures and linking these stimuli to biological perturbations can determine specific chemical exposures of concern, mechanisms and biomarkers of toxicity, and interventions. However, advancement of exposomics is limited by a lack of harmonization of gas chromatography… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(26 citation statements)
references
References 52 publications
0
12
0
Order By: Relevance
“…50 A total of 544 substances were identified across 16 serum pools. Eleven substances were confirmed with analytic standards (Level 1 Identification) 38 in the pooled samples, while only five substances were confirmed in the SRM (confirmed substances are shown in Supporting Information Figure 3; all chemicals that underwent targeted confirmation are provided in Supporting Information Table 1). There were 174 unique substances tentatively identified (Level 2 Identification) through either basic processing (61 unique substances) or CPR processing (117 unique substances).…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…50 A total of 544 substances were identified across 16 serum pools. Eleven substances were confirmed with analytic standards (Level 1 Identification) 38 in the pooled samples, while only five substances were confirmed in the SRM (confirmed substances are shown in Supporting Information Figure 3; all chemicals that underwent targeted confirmation are provided in Supporting Information Table 1). There were 174 unique substances tentatively identified (Level 2 Identification) through either basic processing (61 unique substances) or CPR processing (117 unique substances).…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Chemical Identification and Confidence Level Assignment. Tentative chemical identifications were assigned using the confidence levels proposed by Koelmel et al 38 Levels reported here are Level 1, a confirmed identification made using a chemical standard; Level 2, a probable structure assigned based on favorable matching between experimental MS/MS spectrum and the National Institute of Standards and Technology 2014 Mass Spectral library, version 2.2.07�2014 (NIST 2014); and Level 3, tentative isomer identification where the spectra are similar, but the exact isomer, carbon chain length, or location of functional groups on the carbon chain of a substance is not certain. Further explanations of the types of identifications used in this study can be found in the Supporting Information.…”
Section: ■ Methodsmentioning
confidence: 99%
“… a DF refers to the detection frequency in all 20 brands of masks. b CL refers to the structural confidence level of tentatively identified organic compounds according to the criteria of Koelmel et al A CL of 1 means the chemical has been confirmed vs an analytical standard. A CL of 2 means the chemical could also be other isomers of the same core structure.…”
Section: Resultsmentioning
confidence: 99%
“…Full scan spectral data were deconvoluted into different feature groups (i.e., a group of mass spectral peaks of the same retention time and highly similar peak shapes) and matched to the NIST spectral library (version 2017, National Institute of Standards and Technology). The most probable candidate for each feature group was obtained by filtering key matching parameters (e.g., "score", "SI", and "ΔRI") according to the rules detailed in the Supporting Information, and a confidence level (CL) was assigned to each tentatively identified chemical according to the criteria described by Koelmel et al 36 In addition, for each brand, only chemicals detected in all three masks were reported. For all tentatively identified chemicals, the internal standard corrected peak areas were calculated, and for some of the chemicals with higher values, candidate standards were procured for structural confirmation and quantification.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…Compounds with delta RI less than 20 were deemed reliable. 49 LC-HRMS analysis was conducted using a UHPLC-Orbitrap system (Ultimate 3000/Orbitrap Fusion, Thermo Fisher Scientific) equipped with a UPLC BEH C18 column (50 mm × 2.1 mm × 1.7 μm, Thermo Fisher Scientific). Positive and negative electrospray ionization modes were performed separately.…”
Section: Environmentalmentioning
confidence: 99%