2020
DOI: 10.1016/j.ijbiomac.2020.02.283
|View full text |Cite
|
Sign up to set email alerts
|

Aminotriazolethiol-functionalized chitosan as a macromolecule-based bioinspired corrosion inhibitor for surface protection of stainless steel in 3.5% NaCl

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4
4
1

Relationship

2
7

Authors

Journals

citations
Cited by 78 publications
(15 citation statements)
references
References 45 publications
0
14
0
Order By: Relevance
“…This method can hold debris up to 50 mm and attain 50–65% of the tensile strength of fresh carbon fibers. The most serious risk for this method is the dust generated by the recycling mechanism [ 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 ].…”
Section: Introductionmentioning
confidence: 99%
“…This method can hold debris up to 50 mm and attain 50–65% of the tensile strength of fresh carbon fibers. The most serious risk for this method is the dust generated by the recycling mechanism [ 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 ].…”
Section: Introductionmentioning
confidence: 99%
“…We use a simple methods to modied the surface of CAW, and the corrosion resistance, cytotoxicity, and antibacterial properties was evaluated. In recent years, extensive studies have examined a variety of surface modication methods to improve corrosion resistance and biocompatibility, 21,22 such as chemical vapor deposition, 23 physical vapor deposition, 24 chemical and electrochemical techniques, 25 and thermal 26 and plasma 27 spraying. LPD technology, developed from wet chemical processes, is used widely in the preparation of functional coatings from aqueous solutions.…”
Section: Discussionmentioning
confidence: 99%
“…Polarization experiments were undertaken by potential scanning of the working electrode in the range ±250 mV vs the E OCP . The corrosion inhibition efficiency was evaluated using the data from EIS (η EIS %) and the PDP studies (η PDP %) as , where R ct and R ct MET symbolize the blank and the inhibited charge transfer resistances, respectively; i corr 0 , and i corr MET provide the corresponding corrosion current densities.…”
Section: Methodsmentioning
confidence: 99%
“…Polarization experiments were undertaken by potential scanning of the working electrode in the range ±250 mV vs the E OCP . The corrosion inhibition efficiency was evaluated using the data from EIS (η EIS %) and the PDP studies (η PDP %) as 25,26…”
Section: Methodsmentioning
confidence: 99%