Abstract: Abstract Objective/Scope One of the largest Air-cooled steam condensers in our plant having 16 bays & 32 fans of 4.8m diameter, was observed with high vibrations beyond 100 mm/s, resulting in equipment integrity & HSE concerns. Most importantly, 250 MT/hr of steam has to be vented to atmosphere, if the air-cooler is down. This paper presents the alternate approach adopted which resolved vibration issue, enhanced availability & improved steam syste… Show more