Adverse reaction to metal debris following hip resurfacing

Abstract: We sought to establish the incidence of joint failure secondary to adverse reaction to metal debris (ARMD) following metal-on-metal hip resurfacing in a large, three surgeon, multicentre study involving 4226 hips with a follow-up of 10 to 142 months. Three implants were studied: the Articular Surface Replacement; the Birmingham Hip Resurfacing; and the Conserve Plus. Retrieved implants underwent analysis using a co-ordinate measuring machine to determine volumetric wear. There were 58 failures associated with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

3
111
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 353 publications
(123 citation statements)
references
References 40 publications
3
111
0
Order By: Relevance
“…Failure due to ALTR has previously been described for MoM bearing surfaces and modular junctions at the head-neck and neck-stem [4,9-14,21-23,35,38,39]. The purposes of this study were to compare implant-based differences in periprosthetic tissue structure, organization, corrosion product morphology, and cellular composition by conventional histology and immunohistochemistry in ALTR resulting from two common implant configurations.…”
Section: Discussionmentioning
confidence: 99%
“…Failure due to ALTR has previously been described for MoM bearing surfaces and modular junctions at the head-neck and neck-stem [4,9-14,21-23,35,38,39]. The purposes of this study were to compare implant-based differences in periprosthetic tissue structure, organization, corrosion product morphology, and cellular composition by conventional histology and immunohistochemistry in ALTR resulting from two common implant configurations.…”
Section: Discussionmentioning
confidence: 99%
“…Selection criteria for the high-risk group were: serum cobalt >5 μg/l [10], female sex [12, 13], hip pain [14] and a high cup inclination angle >45°, which is considered to be out of the safe zone in resurfacing prosthesis [16, 24]. Inclusion criteria for the low-risk group were the opposing criteria (male sex, no hip pain, cup inclination <45°, and serum cobalt <5 μg/l).…”
Section: Methodsmentioning
confidence: 99%
“…Both positive [2,11] and negative reports [25,34,35,37,61] have emerged with regard to using MoM bearings. There are likely many risks that could trigger a need for MoM revision.…”
Section: Introductionmentioning
confidence: 99%