DOI: 10.1007/978-3-540-68585-2_34
|View full text |Cite
|
Sign up to set email alerts
|

Acoustic Event Detection: SVM-Based System and Evaluation Setup in CLEAR’07

Abstract: Abstract. In this paper, the Acoustic Event Detection (AED) system developed at the UPC is described, and its results in the CLEAR evaluations carried out in March 2007 are reported. The system uses a set of features composed of frequency-filtered band energies and perceptual features, and it is based on SVM classifiers and multi-microphone decision fusion. Also, the current evaluation setup and, in particular, the two new metrics used in this evaluation are presented.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Publication Types

Select...
3
1
1

Relationship

3
2

Authors

Journals

citations
Cited by 26 publications
(27 citation statements)
references
References 4 publications
(5 reference statements)
0
27
0
Order By: Relevance
“…Unfortunately, we were not able to explore it more due to the low size of the evaluation corpus. Future work will be devoted to the application of the FI to multi-microphone classification (and also detection) of acoustic events with a much larger dataset recorded in meeting rooms [17]. Also, a further improvement can come from the fact that signals captured from microphones placed at different positions in the room may carry different information about the acoustic events taking place in it.…”
Section: Resultsmentioning
confidence: 99%
“…Unfortunately, we were not able to explore it more due to the low size of the evaluation corpus. Future work will be devoted to the application of the FI to multi-microphone classification (and also detection) of acoustic events with a much larger dataset recorded in meeting rooms [17]. Also, a further improvement can come from the fact that signals captured from microphones placed at different positions in the room may carry different information about the acoustic events taking place in it.…”
Section: Resultsmentioning
confidence: 99%
“…In our experiments, the CLEAR'07 evaluation database is used [2]. It consists of 25 interactive seminars, approximately 30min-long that have been recorded by AIT, ITC, IBM, UKA, and UPC in their smart-rooms.…”
Section: Database and Metricmentioning
confidence: 99%
“…The SVM-based AED system used in the present work is the one that was also used for the AED evaluations in CLEAR 2007 [2] with slight modifications. The sound signal from a single MarkIII array microphone is down-sampled to 16 kHz, and framed (frame length/shift is 30/10ms, a Hamming window is used).…”
Section: Svm-based Aed Systemmentioning
confidence: 99%
See 2 more Smart Citations