2018
DOI: 10.1111/clr.13142
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review

Abstract: Objective: The aim of this systematic review was to identify, review, analyze, and summarize available evidence on the accuracy of linear measurements when using maxillofacial cone beam computed tomography (CBCT) specifically in the field of implant dentistry. Material and methods:The search was undertaken in April 2017 in the National Library of Medicine database (Medline) through its online site (PubMed), followed by searches in the Cochrane, EMBASE, ScienceDirect, and ProQuest Dissertation and Thesis databa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
141
1
3

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 141 publications
(151 citation statements)
references
References 95 publications
6
141
1
3
Order By: Relevance
“…[14][15][16][17] However, the accuracy of reformatted CBCT images is affected by technical parameters that could depend on the CBCT system, such as nominal resolution, image quality, voxel size, kV, mA, number of basis images, field of view (FOV), and the algorithm of the software used in the acquisition and reconstruction of dimensional measurements. 12,18,19 Advanced CBCT systems with high spatial resolution, submillimeter voxel sizes, small FOV, and a smaller focal spot, are considered more accurate in regard to linear measurements. 18 Although some CBCT studies have been conducted to analyze bone thickness in maxillary and mandibular teeth, the information regarding bone thickness in the apical region have been under-represented.…”
Section: Cone-beam Computed Tomography (Cbct) Is Anmentioning
confidence: 99%
See 1 more Smart Citation
“…[14][15][16][17] However, the accuracy of reformatted CBCT images is affected by technical parameters that could depend on the CBCT system, such as nominal resolution, image quality, voxel size, kV, mA, number of basis images, field of view (FOV), and the algorithm of the software used in the acquisition and reconstruction of dimensional measurements. 12,18,19 Advanced CBCT systems with high spatial resolution, submillimeter voxel sizes, small FOV, and a smaller focal spot, are considered more accurate in regard to linear measurements. 18 Although some CBCT studies have been conducted to analyze bone thickness in maxillary and mandibular teeth, the information regarding bone thickness in the apical region have been under-represented.…”
Section: Cone-beam Computed Tomography (Cbct) Is Anmentioning
confidence: 99%
“…12,18,19 Advanced CBCT systems with high spatial resolution, submillimeter voxel sizes, small FOV, and a smaller focal spot, are considered more accurate in regard to linear measurements. 18 Although some CBCT studies have been conducted to analyze bone thickness in maxillary and mandibular teeth, the information regarding bone thickness in the apical region have been under-represented.…”
Section: Cone-beam Computed Tomography (Cbct) Is Anmentioning
confidence: 99%
“…Three cases A, B, and C, defined as sparse 12 projections' input, and the n interp = 96, 144, and 168. The A, B, and C result sets are quoted at the first, middle, and last projections of each segment ℩ i (i = [1,8], I ∈ N). The ℩ i is defined in degrees of (0,45), (45,90), (90,135), .…”
Section: Results Of the Sa2ir Algorithm's Reconstruction Simulationmentioning
confidence: 99%
“…To the best of our knowledge, this is the first radiographic study evaluating REF and PRD dimensions using CBCT. This 3D clinical imaging technique has been shown to provide reliable data with regard to object dimensions and linear measurements in comparison to the gold standard (8).…”
Section: Discussionmentioning
confidence: 99%