2003
DOI: 10.1109/tasc.2003.813068
|View full text |Cite
|
Sign up to set email alerts
|

AC loss measurement of HTS coils with ferromagnetic disks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
26
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 29 publications
(27 citation statements)
references
References 1 publication
1
26
0
Order By: Relevance
“…The HTS coil comprises 10 double pancake coils wound by the Bi2223/Ag tape whose specification is also listed in Table I. The HTS coils have been manufactured for the research of the LC resonance type fault current limiter developed by the National Institute of Advanced Industrial Science and Technology [1], [2]. Coil A is wound with the single Bi2223/Ag tape without the winding tension but impregnated with epoxy resin.…”
Section: A Specifications Of Hts Coilmentioning
confidence: 99%
See 1 more Smart Citation
“…The HTS coil comprises 10 double pancake coils wound by the Bi2223/Ag tape whose specification is also listed in Table I. The HTS coils have been manufactured for the research of the LC resonance type fault current limiter developed by the National Institute of Advanced Industrial Science and Technology [1], [2]. Coil A is wound with the single Bi2223/Ag tape without the winding tension but impregnated with epoxy resin.…”
Section: A Specifications Of Hts Coilmentioning
confidence: 99%
“…The mechanical losses are mainly caused by the frictional vibration and the nonlinear deformation of the coil winding. In another collaboration, the mechanical losses produced in the HTS coil have been studied [1], [2]. The main objective of this study is to investigate the electromagnetic AC loss characteristics of a solenoid HTS Manuscript coil consisting of pancake coils.…”
Section: Introductionmentioning
confidence: 99%
“…Generally, magnetization losses are dominant among the total losses of HTS coils, and the total AC losses of coils can be estimated from the magnetic field distribution and the measured magnetization losses of short samples by applying perpendicular and parallel magnetic fields to the tape surface [1].…”
Section: Introductionmentioning
confidence: 99%
“…To demonstrate this method, the authors measured the total losses of HTS coils wound with Bi2223 silver sheathed tape superconductors and having a volume of 1 L, inductance of 170 mH, and average critical current of 16.7 A (defined by 1 ), with and without attached ferromagnetic disks [1]. The total losses measured by the boil-off method were 10 to 100 times greater than that forecast from the magnetization losses of short samples.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation