Absorption‐mode spectra on the dynamically harmonized Fourier transform ion cyclotron resonance cell

Abstract: The manuscript demonstrates absorption-mode spectra from Nikolaev's ICR cell, which will be of interest to the community. The improved relative peak intensities and immediate identification of harmonic peaks will facilitate data interpretation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
39
2

Year Published

2014
2014
2021
2021

Publication Types

Select...
8

Relationship

6
2

Authors

Journals

citations
Cited by 37 publications
(44 citation statements)
references
References 24 publications
3
39
2
Order By: Relevance
“…Thus, when combined with the infinity cell concept, both storage and excitation potential are close to the theoretical optimum. The performance is evaluated in a collaborative article between Bruker, the University of Warwick and Nikolaev …”
Section: Fourier Transform Ion Cyclotron Resonance Msmentioning
confidence: 99%
“…Thus, when combined with the infinity cell concept, both storage and excitation potential are close to the theoretical optimum. The performance is evaluated in a collaborative article between Bruker, the University of Warwick and Nikolaev …”
Section: Fourier Transform Ion Cyclotron Resonance Msmentioning
confidence: 99%
“…The mass spectrum was phase-corrected using the Autophaser 6.0 phase correction software [25][26][27][28][29][30][31][32]. All onedimensional (1D) spectra were first externally calibrated in the solariXControl software (Bruker Daltonics, Billerica, MA, USA) using Agilent ESI-L Low Concentration Tuning Mix (Agilent Technologies, Stockport, United Kingdom), and then internally calibrated against the theoretical m/z values of the ions generated by cholesterol using the quadratic calibration function within Data Analysis 4.0 (Bruker Daltonik GmbH, Bremen, Germany) [33].…”
Section: Control Mass Spectra and Product-ion Spectramentioning
confidence: 99%
“…Automated phase correction for absorption mode mass spectra was achieved with the development of the Autophaser software by Kilgour et al [34][35][36]. Phase correction for absorption mode mass spectrometry is now integral to data processing for FT-ICR MS, for various geometries of ICR cells [35,37]. Phasecorrected absorption-mode data from the dynamically harmonized ICR cell has allowed the highest published FT-ICR MS resolving power (R = 32,000,000 at m/z 400) [37].…”
Section: Introductionmentioning
confidence: 99%
“…Phase correction for absorption mode mass spectrometry is now integral to data processing for FT-ICR MS, for various geometries of ICR cells [35,37]. Phasecorrected absorption-mode data from the dynamically harmonized ICR cell has allowed the highest published FT-ICR MS resolving power (R = 32,000,000 at m/z 400) [37]. The effect of various instrument parameters on phase functions has also been studied [33].…”
Section: Introductionmentioning
confidence: 99%