2015
DOI: 10.1016/j.ajem.2014.11.029
|View full text |Cite
|
Sign up to set email alerts
|

Abdominal oxygen saturation for monitoring return of spontaneous circulation in out-of-hospital cardiac arrest using near infrared spectrophometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0
1

Year Published

2015
2015
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(13 citation statements)
references
References 27 publications
0
12
0
1
Order By: Relevance
“…There were 15 full‐text articles and five conference abstracts (Table ). Most included studies measured oximetry levels on the forehead, with only one measuring it on the abdomen . Multiple types of somatic oximeters were used.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…There were 15 full‐text articles and five conference abstracts (Table ). Most included studies measured oximetry levels on the forehead, with only one measuring it on the abdomen . Multiple types of somatic oximeters were used.…”
Section: Resultsmentioning
confidence: 99%
“…Among the included studies, only the five abstracts were evaluated as being at high risk of bias . Nine of the remaining studies were at intermediate risk of bias and six were at low risk of bias . The description of the risk of bias for each included study is presented in Table and specified in Data Supplement S1.…”
Section: Resultsmentioning
confidence: 99%
“…Kritik hastalarda BrSO 2 takibi ile ilgili çalışmalar olmasına karşın, BSOO'nın bakıldığı az sayıda çalış-ma bulunmaktadır (18,19) . Çalışmamızda, BrSO 2 'nin korunduğu ve tedavi ile anlamlı değişiklik gösterme-diği, KTA, SS, SpO 2 değerleri ve ek olarak SrSO 2 değerinin anlamlı olarak tedavi ile düzeldiği görül-müştür.…”
Section: Gereç Ve Yöntemunclassified
“…For example, a control experiment might be to place oximeter probes both on the head and on another part of the body. Near infrared devices easily measure regional perfusion when placed on the arm or abdomen . Compartments will either differ or vary together.…”
Section: Introductionmentioning
confidence: 99%
“…Near infrared devices easily measure regional perfusion when placed on the arm or abdomen. 14,15 Compartments will either differ or vary together. Attention to these technical issues is important when commenting on organ-specific physiology.…”
mentioning
confidence: 99%