2016
DOI: 10.1186/s40658-016-0151-6
|View full text |Cite
|
Sign up to set email alerts
|

Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT

Abstract: BackgroundThe use of selective internal radiation therapy (SIRT) is rapidly increasing, and the need for quantification and dosimetry is becoming more widespread to facilitate treatment planning and verification. The aim of this project was to develop an anthropomorphic phantom that can be used as a validation tool for post-SIRT imaging and its application to dosimetry.MethodThe phantom design was based on anatomical data obtained from a T1-weighted volume-interpolated breath-hold examination (VIBE) on a Sieme… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
62
0
1

Year Published

2017
2017
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 64 publications
(70 citation statements)
references
References 19 publications
5
62
0
1
Order By: Relevance
“…Leng et al published a comparable range of 50 to 75 HU (TangoBlackPlus) and 105 to 125 HU (VeroWhitePlus) . Similar results were also obtained by Gear et al with (96 ± 15) HU (TangoBlackPlus) and (127 ± 15) HU (VeroWhitePlus) …”
Section: Discussionsupporting
confidence: 74%
“…Leng et al published a comparable range of 50 to 75 HU (TangoBlackPlus) and 105 to 125 HU (VeroWhitePlus) . Similar results were also obtained by Gear et al with (96 ± 15) HU (TangoBlackPlus) and (127 ± 15) HU (VeroWhitePlus) …”
Section: Discussionsupporting
confidence: 74%
“…(I) (a) Lesion design, (b) Lesion filling, (c) Connection port, ( II ) (a) Lesion and support rods placement at the phantom base, (b) Phantom base fitted to the phantom body . Figure license: Gear, et al #bib2016, Abdo‐Man: 3D printed anthropomorphic phantom for validating quantitative SIRT .…”
Section: Resultsmentioning
confidence: 99%
“…The rendered outcomes represent the tissues exposed to radiation, as well as the amount of absorbed dose in the tumors and the healthy tissues. Abdo‐Man [GCC*16] involves a pipeline (imaging, organ definition, 3D mesh generation, 3D printing) for the production of a 3D printed anthropomorphic phantom that can be used as a validation tool for dosimetry.…”
Section: Taxonomy and Presentation Of Previous Work In Vc For Rtmentioning
confidence: 99%
“…Within this category, we encounter also most of the integrable applications—in particular, within the spatial evaluation subgroup. It is of particular interest that chronologically older works [HST87, LFP*90, MYKO91, IFP95, IFP96, IFP97] that were mainly concerned with 2D representations are well‐established in clinical routine, while newer 3D approaches [GDF*00, LCS*13, FC16, GCC*16] have remained at a developmental stage. A lot of VR/AR approaches are also, at least partially, integrable—the most important example being the work of Ward et al [WPB*11].…”
Section: Taxonomy and Presentation Of Previous Work In Vc For Rtmentioning
confidence: 99%
See 1 more Smart Citation