2017
DOI: 10.1155/2017/5031505
|View full text |Cite
|
Sign up to set email alerts
|

A Stability Analysis of Thermostatically Controlled Loads for Power System Frequency Control

Abstract: Thermostatically controlled loads (TCLs) are a flexible demand resource with the potential to play a significant role in supporting electricity grid operation. We model a large number of identical TCLs acting autonomously according to a deterministic control scheme to provide frequency response as a population of coupled oscillators. We perform stability analysis to explore the danger of the TCL temperature cycles synchronising: an emergent phenomenon often found in populations of coupled oscillators and predi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(21 citation statements)
references
References 45 publications
(63 reference statements)
0
21
0
Order By: Relevance
“…100 per group unless stated otherwise 3 ). There are an estimated 10.1M households in GB with a fridge, and 18.6M with a fridge-freezer [5]. Each combination of parameter values is explored with 36 simulations spanning 12 months during 2015-16, and each simulation runs for 10 days with 1s resolution.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…100 per group unless stated otherwise 3 ). There are an estimated 10.1M households in GB with a fridge, and 18.6M with a fridge-freezer [5]. Each combination of parameter values is explored with 36 simulations spanning 12 months during 2015-16, and each simulation runs for 10 days with 1s resolution.…”
Section: Methodsmentioning
confidence: 99%
“…The associate editor coordinating the review of this manuscript and approving it for publication was Siqi Bu. 1 See, for example, [4], [5] for a description of the different types of frequency response and balancing services more widely. During 2017-18 (and similarly in previous years) the SO in Great Britain (GB) paid approximately £140M for response [6] below the nominal value (50Hz in GB) frequency response providers increase generation (or decrease demand), and vice versa when the frequency rises above nominal.…”
Section: Or Frequency Regulation When the Frequency Fallsmentioning
confidence: 99%
See 2 more Smart Citations
“…By analyzing a large number of drivers' long driving mode, road conditions, weather conditions, and so on, the influence of the electric vehicle at different driving speed, acceleration, and temperature on the energy consumption rate is calculated. However, in the estimation of electric vehicle mileage, it does not consider the influence of motor control strategy [16,17]. Therefore, it is necessary to study the regenerative braking strategy of a dual-axis drive electric vehicle [18].…”
Section: Introductionmentioning