2017
DOI: 10.1016/j.snb.2016.07.164
|View full text |Cite
|
Sign up to set email alerts
|

A self-contained microfluidic in-gel loop-mediated isothermal amplification for multiplexed pathogen detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
29
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 52 publications
(30 citation statements)
references
References 40 publications
1
29
0
Order By: Relevance
“…Microfluidic technology is a new approach of POC that can overcome the limitation of conventional POC by providing improvements of fewer reagents consumption, increased portability, simplicity, and reduced reaction time [61]. It involves the preloading of the master mix containing all the reaction components in microliter volumes into a sample loading well where it moves into the reaction chamber and the amplicon detected at another segment of the setup.…”
Section: Microfluidic Platformmentioning
confidence: 99%
See 1 more Smart Citation
“…Microfluidic technology is a new approach of POC that can overcome the limitation of conventional POC by providing improvements of fewer reagents consumption, increased portability, simplicity, and reduced reaction time [61]. It involves the preloading of the master mix containing all the reaction components in microliter volumes into a sample loading well where it moves into the reaction chamber and the amplicon detected at another segment of the setup.…”
Section: Microfluidic Platformmentioning
confidence: 99%
“…It involves the preloading of the master mix containing all the reaction components in microliter volumes into a sample loading well where it moves into the reaction chamber and the amplicon detected at another segment of the setup. Many studies reported different setup, for example, Chen et al [61] used in-gel microfluidic LAMP for multiplex detection of foodborne pathogens. Chung et al [62] designed a microfluidic chip module for detecting murine norovirus in oysters using charge switchable micro-bead beating.…”
Section: Microfluidic Platformmentioning
confidence: 99%
“…To facilitate their deployment in POC settings, LAMP reagents can be stored in dried form with a shelf life of up to 30 days at 56 °C [ 151 ]. Chen et al [ 152 ] were able to store reagents within a low-melting-point agarose gel maintained at 4 °C for long-term storage.…”
Section: Amplificationmentioning
confidence: 99%
“…The sensitivity of the multiplex device was found to be 100 orders of magnitude better than typical PCR and is comparable to the sensitivity of real-time PCR. Chen [ 152 ] also demonstrated multiplex detection of four bacterial DNA targets with a detection sensitivity of three copies/μL with agarose gel prestoring.…”
Section: Amplificationmentioning
confidence: 99%
“…It takes up to one week to determine the specific pathogen microorganisms. Therefore, different methods of pathogen detections are in high demand in the food industry to avoid the spread of any bacterial diseases from food poisoning [ 18 , 19 ]. The detection methods can be categorized into the following groups: conventional methods and various sensor-based methods.…”
Section: Introductionmentioning
confidence: 99%