2015
DOI: 10.3906/elk-1301-24
|View full text |Cite
|
Sign up to set email alerts
|

Abstract: Abstract:In this paper, a robust algorithm for fault diagnosis of power system equipment based on a failure-sensitive matrix (FSM) is presented. The FSM is a dynamic matrix structure updated by multiple measurements (online) and test results (offline) on the systems. The algorithm uses many different artificial intelligence and expert system methods for adaptively detecting the location of faults, emerging failures, and causes of failures. In this algorithm, all data obtained from the power transformer, which … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 45 publications
0
1
0
Order By: Relevance
“…In recent years, with the rapid development of industrial economy in our country, the fast-growing demand for power, power supply, serious overload, transformer accident rate is increasing year by year. With the change in operating years and an increase in operating condition, power transformers may occur in various forms of failure or fault indication [1], transformer condition assessment it is reflected from its operating state of various important factors starting from the macro to the transformer run security state overall assessment, by comparing historical data shows that China's current part of power transformer condition assessment method of distribution transformers provinces overhaul costs decreased significantly [2]. Dissolved gas analysis (dissolved gas analysis, DGA) technology can accurately and reliably detect potential defects transformer progressive development.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, with the rapid development of industrial economy in our country, the fast-growing demand for power, power supply, serious overload, transformer accident rate is increasing year by year. With the change in operating years and an increase in operating condition, power transformers may occur in various forms of failure or fault indication [1], transformer condition assessment it is reflected from its operating state of various important factors starting from the macro to the transformer run security state overall assessment, by comparing historical data shows that China's current part of power transformer condition assessment method of distribution transformers provinces overhaul costs decreased significantly [2]. Dissolved gas analysis (dissolved gas analysis, DGA) technology can accurately and reliably detect potential defects transformer progressive development.…”
Section: Introductionmentioning
confidence: 99%