A review of physical and engineering factors potentially affecting shear wave elastography

Abstract: It has been recognized that tissue stiffness provides useful diagnostic information, as with palpation as a screening for diseases such as cancer. In recent years, shear wave elastography (SWE), a technique for evaluating and imaging tissue elasticity quantitatively and objectively in diagnostic imaging, has been put into practical use, and the amount of clinical knowledge about SWE has increased. In addition, some guidelines and review papers regarding technology and clinical applications have been published,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 122 publications
0
9
0
Order By: Relevance
“…Although various methods for measuring the SWS have been proposed, [36][37][38][39] in this study, we measured the SWS using the TOF method based on linear regression. 33,39) The method for measuring the SWS is shown in Fig.…”
Section: Sws Measurementmentioning
confidence: 99%
“…Although various methods for measuring the SWS have been proposed, [36][37][38][39] in this study, we measured the SWS using the TOF method based on linear regression. 33,39) The method for measuring the SWS is shown in Fig.…”
Section: Sws Measurementmentioning
confidence: 99%
“…Combination of both ultrasound and magnetic elastography imaging techniques has shown significant improvements in the diagnosis 329 . Resolution limitations are still an issue in the application of elastography techniques and novel mathematical models are needed to interpret the complex dataset obtained 330 …”
Section: Clinical Practice and Development Of New Technologies In Mec...mentioning
confidence: 99%
“…329 Resolution limitations are still an issue in the application of elastography techniques and novel mathematical models are needed to interpret the complex dataset obtained. 330 Mechanical indentation by means of AFM and indenters has proven to be a reliable technique to obtain cancer mechanical biomarkers by several research works, 120,121 and companies like Artidis are developing mechanical indentation technology based on AFM of cancer biopsies for precision clinical diagnostic 51,331 (Figure 5F). ARTI-DIS ® uses tumoral biopsies extracted routinely in patients where a mass has been detected through imaging techniques and performs indentation measurements to detect possible mechanical biomarkers.…”
Section: Agingmentioning
confidence: 99%
“…These artifacts can cause inaccurate shear wave speed estimates. 16 Multidimensional directional filters reduce reflection artifacts by attenuating shear waves traveling in the reflected direction. 17,18 Because the directional filter is applied in the Fourier domain, shear wave data that are spatially undersampled can lead to aliasing effects and reductions in filter efficacy.…”
Section: Introductionmentioning
confidence: 99%