A review of enzymatic uric acid biosensors based on amperometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
88
0
4

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 177 publications
(100 citation statements)
references
References 156 publications
3
88
0
4
Order By: Relevance
“…Although there are reports in the literature on the trace elements content in plants, we are still far from the point of knowing exactly the mechanisms of action and the formation of active constituents for ech medicinal plants. Major and Minor elements have very important functions and it is believed a key component of proteins such as haemoprotein and haemoglobin which play role in biochemical functions and essential enzyme system even in low doses (Erden & Kılıç, 2013). 1760.28 ± 12.39 Each value is the mean ± standard deviation of five determinations, Values bearing the same letter showed no significant difference (P < 0.05).…”
Section: Mineral Contentmentioning
confidence: 99%
“…Although there are reports in the literature on the trace elements content in plants, we are still far from the point of knowing exactly the mechanisms of action and the formation of active constituents for ech medicinal plants. Major and Minor elements have very important functions and it is believed a key component of proteins such as haemoprotein and haemoglobin which play role in biochemical functions and essential enzyme system even in low doses (Erden & Kılıç, 2013). 1760.28 ± 12.39 Each value is the mean ± standard deviation of five determinations, Values bearing the same letter showed no significant difference (P < 0.05).…”
Section: Mineral Contentmentioning
confidence: 99%
“…In another study, Tang et al demonstrated antigen-antibody interaction via GOD conjugated hollow gold-silver microspheres (AuAgHSs) further coupled using Prussian blue NPs (an artificial catalase), on a graphene-based immunosensor [117]. Pesticidal study [96] Hba1c biosensor Determining glycated hemoglobin [97] Piezoelectric biosensors Detecting carbamate and organophosphate [98] Uric acid biosensors Diagnosis of various clinical abnormalities or illness (e.g., diagnosis of cardiovascular disease) [99,100] Glucose oxidase electrode biosensors Measuring of glucose in biological sample of diabetic patient [101] Quartz-crystal biosensors Detection of proteins at ultrahigh-sensitive level in liquids [102] Optical Polyacrylamide based hydrogel biosensors Immobilization of biomolecules [30] Silicon biosensor For biosensing, bioimaging, and in cancer therapy [103,104] Microfabricated biosensor In novel drug delivery (e.g., in optical corrections) [105] Fluorescence tagged/Genetically encoded biosensor Investigation of various biological process and molecular systems in the cell [27,[106][107][108] Electrochemical or optical Nanomaterials biosensors For diagnosis and in drug delivery [32,93,[109][110][111][112][113][114] …”
Section: Glucose Monitoringmentioning
confidence: 99%
“…[14][15][16] 전기화학 방법을 이용한 uric acid의 측정은 다양한 전극 위에서 효소 없이 (무 효소, nonenzymatic) 측정 되는 방법과 효소를 포함하여 (enzymatic) 측정하는 방식으로 나뉜다. 4 를 mediator로써 사용하 였다. (Fig.…”
Section: -5)unclassified