1999
DOI: 10.1002/(sici)1099-1565(199911/12)10:6<307::aid-pca477>3.0.co;2-l
|Get access via publisher |Summarize |Cite
A rapid high-performance liquid chromatography method to measure lipophilic antioxidants in stressed plants: simultaneous determination of carotenoids and tocopherols
Search citation statements
Paper Sections
Select...
177
13
1
0
Citation Types
0
29
0
0
Year Published
1999
2026
Publication Types
Select...
176
6
5
4
Relationship
9
182
Authors
Journals
Cited by 191 publications
(29 citation statements)
References 35 publications
0
29
0
0
“…The extraction of chlorophylls and carotenoids from lyophilized leaves was conducted using pure acetone (100% v / v , HPLC grade) according to the method outlined by García-Plazaola and Becerril [ 47 ]. The analysis was performed via high-performance liquid chromatography (HPLC) on an Agilent Technologies 1200 series system, employing a Waters Spherisorb C-18 column (5.0 µm ODS1, 4.6 × 250 mm).…”
Section: Methods
mentioning
confidence: 99%
“…The extraction of chlorophylls and carotenoids from lyophilized leaves was conducted using pure acetone (100% v / v , HPLC grade) according to the method outlined by García-Plazaola and Becerril [ 47 ]. The analysis was performed via high-performance liquid chromatography (HPLC) on an Agilent Technologies 1200 series system, employing a Waters Spherisorb C-18 column (5.0 µm ODS1, 4.6 × 250 mm).…”
Section: Methods
mentioning
confidence: 99%
“…Finally, by high‐performance liquid chromatography method, the content of zeaxanthin, lutein and β‐carotene was ascertained according to the method of García‐Plazaola and Becerril (1999) with few modifications. The instrument was an Agilent (California, USA) HPLC system, composed of a solvent degasser (1100 series), quaternary pump (1100 series), thermostated column compartment (1100 series), autosampler (1260 series) and diode array detector (DAD, 1200 series).…”
Section: Methods
mentioning
confidence: 99%
“…Pigments were analysed using a reverse‐phase Waters (Milford, MA, USA) high‐performance liquid chromatography (HPLC) system following the method of García‐Plazaola and Becerril (1999) with the modifications described in García‐Plazaola and Becerril (2001) using 15 μL of sample extract. A photodiode array (PDA) detector (Waters model 996) was used to identify and quantify photosynthetic pigments (violaxanthin, antheraxanthin, zeaxanthin, lutein, lutein epoxidate, chlorophyll a and b, and α‐ and β‐carotene) in the range 250–700 nm.…”
Section: Methods