A Preliminary Proposal for Quality Control Assessment and Harmonization of Leukocytes Morphology-Structural Parameters (Cell Population Data Parameters)

Abstract: SummaryBackgroundThe cell population data (CPD) measured by Sysmex XN-9000 can be used for screening many hematological and non-hematological disorders. Since little information is available on harmonization of CPD among different instrumentation and clinical laboratories, this study aimed at assessing the current degree of CPD harmonization between separate Sysmex XN modules allocated to the same laboratory.MethodsA total number of 78291 data were used for verification of within-run imprecision, analyzers har… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 21 publications
(27 reference statements)
0
8
0
Order By: Relevance
“…9,10 Here we considered the clinical utility of CPD parameters, LY-Y parameter showed a particular trend in our study with negative correlation in sepsis cases, which was consistent with Buoro et al However, the major disadvantage of these CPD parameters were less analytical quality specification and harmonization among different instruments and clinical laboratories. 11 This was rectified to an extent by the study done on quality control assessment and harmonization of CPD parameters by Seghezzi et al They found minimal imprecision for all CPD parameters except for those reflecting width of dispersion .Though in our study, no imprecision test was performed, combining our statistical analysis with Seghezzi et al we would like to streamline our findings to all CPD parameters with exception NE-SFC, MO-Z, LY-Y and those reflecting width of dispersion would aid in early diagnosis of sepsis.…”
Section: Discussionmentioning
confidence: 99%
“…9,10 Here we considered the clinical utility of CPD parameters, LY-Y parameter showed a particular trend in our study with negative correlation in sepsis cases, which was consistent with Buoro et al However, the major disadvantage of these CPD parameters were less analytical quality specification and harmonization among different instruments and clinical laboratories. 11 This was rectified to an extent by the study done on quality control assessment and harmonization of CPD parameters by Seghezzi et al They found minimal imprecision for all CPD parameters except for those reflecting width of dispersion .Though in our study, no imprecision test was performed, combining our statistical analysis with Seghezzi et al we would like to streamline our findings to all CPD parameters with exception NE-SFC, MO-Z, LY-Y and those reflecting width of dispersion would aid in early diagnosis of sepsis.…”
Section: Discussionmentioning
confidence: 99%
“…Along the lack of harmonization among different instruments and clinical laboratories, another disadvantage of these CPD parameters is less analytical quality specification. Metrological issues, such as stability, quality control targets and harmonization of CPD, are now under intense evaluation (43,44).…”
Section: Cpd: Opportunity and Weaknessmentioning
confidence: 99%
“…Most of the studies performed in this field so far have been carried out using the hematological analyzer of the Sysmex® laboratory, since it is one of the few that incorporate CPD parameters. 15,18 These parameters prove to be interesting in several aspects as biomarkers, in addition to providing information on changes in leukocytes in a quantitative way, they are obtained very quickly and more accurately during automated differential analysis without additional sample requirements, in an objective and cost-effective manner, They are considered very advantageous when working and analyzing in the laboratory, being useful for the management of hematological pathology, neoplasm and infection, being postulated as predictive and novel parameters in the detection of infection and sepsis. 20 Regarding the results obtained from CPD in this study, they are in agreement with some published studies 2,9,10,12 where of the CPD parameters studied, they suggest that MON-X and NEU-Y parameters may provide useful information in the management of septic patients and be of CPD the best candidates as biomarkers.…”
Section: Discussionmentioning
confidence: 99%
“…12,13,15,16 Most of the studies performed in this field to date have been carried out using the hematological analyzer of the Sysmex® laboratory since it is one of the few that incorporate CPD parameters. [17][18][19][20] This is one of the first studies to utilize the BC 6800 Plus Mindray® analyzer to obtain CPD parameters data for neutrophils (NEU), lymphocytes (LYM) and monocytes (MON). The emitted optical signals indicate changes in internal cellular complexity (NEU-X, LYM-X and MON-X), nucleic acid content (NEU-Y, LYM-Y, MON-Y) and cell size (NEU-Z, LYM-Z, MON-Z).…”
Section: Introductionmentioning
confidence: 99%