2013
DOI: 10.1109/mei.2013.6457597
|View full text |Cite
|
Sign up to set email alerts
|

A novel method for ultra-high-frequency partial discharge localization in power transformers using the particle swarm optimization algorithm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
55
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 63 publications
(55 citation statements)
references
References 16 publications
0
55
0
Order By: Relevance
“…It is known that the EMW cannot be transmitted through the conductors like iron core and copper conductors, while it can be propagated through dielectrics suffering some more attenuation [6]. The most favorable finding was that the PD EMW could be transmitted through the radial oil gaps of the windings, just suffering some more attenuation.…”
Section: The Basis Of the Uhf Pd Localizationmentioning
confidence: 99%
See 2 more Smart Citations
“…It is known that the EMW cannot be transmitted through the conductors like iron core and copper conductors, while it can be propagated through dielectrics suffering some more attenuation [6]. The most favorable finding was that the PD EMW could be transmitted through the radial oil gaps of the windings, just suffering some more attenuation.…”
Section: The Basis Of the Uhf Pd Localizationmentioning
confidence: 99%
“…It is possible to detect and locate PD defects in the early stage of development by measuring and analyzing PD data and take suitable maintenance and repair action. Since now several detection and localization methods like electrical [1][2][3][4], acoustic [5] and ultra-high frequency (UHF) detection [6][7][8][9][10][11] methods have been used in the power transformer. Although the electrical PD detection is sensitive to weak PD activities, it could only predict the turn number of the winding in which PD occurs (1-D localization).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the existing research of PD online monitoring focus on signal de-noising [3][4][5][6], PD sources location [7] and pattern recognition [8][9][10][11], PD severity assessment was rarely involved. To evaluate PD severity, the insulation dielectric property of GIS is the basic characteristic of the PD development process.…”
Section: Introductionmentioning
confidence: 99%
“…INTRODUCTION The quality of the insulation in high voltage equipment is a key issue to keep them functioning [1][2][3][4][5][6][7][8][9][10][11][12]. Electric field of high levels in this equipment produces degradation of insulating parts of the apparatus.…”
mentioning
confidence: 99%