2013
DOI: 10.1016/j.ijrobp.2013.06.372
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Framework for User-Intervened Correction of Deformable Registration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…Compared with the previous study of LC contouring on MRI, a new scanning sequence (breath holding-DE-MRI) and multiperiod scanning were applied in our study [18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35]. Though breathing control can decrease respiratory movement-associated artifacts, our results showed that LC CT was smaller than the LC derived from MRI regardless of the scanning sequence used.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Compared with the previous study of LC contouring on MRI, a new scanning sequence (breath holding-DE-MRI) and multiperiod scanning were applied in our study [18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35]. Though breathing control can decrease respiratory movement-associated artifacts, our results showed that LC CT was smaller than the LC derived from MRI regardless of the scanning sequence used.…”
Section: Discussionmentioning
confidence: 99%
“…Finally, based on automatic deformation, the Reg Reveal tool was used for evaluating DIR in the primary area of concern [ 22 ]. Reg Refine would only be used in the event that, while evaluating the initial deformation with Reg Reveal, it was determined a poor alignment was identified that needs to be fixed [ 23 ]. Converting local alignments, defined as an assemblage of local alignments to create a deformable registration, was used in our study.…”
Section: Methodsmentioning
confidence: 99%
“…Finally, based on automatic deformation, the Reg Reveal tool was used for evaluating DIR in the primary area of concern [22] . Reg Re ne would only be used in the event that, while evaluating the initial deformation with Reg Reveal, it was determined a poor alignment was identi ed that needs to be xed [23] . Converting local alignments, de ned as an assemblage of local alignments to create a deformable registration, was used in our study.…”
Section: Deformable Image Registration (Dir) Proceduresmentioning
confidence: 99%
“…Three registration algorithms were chosen for evaluation using the swine lung, these include the fast-symmetric forces demons (Vercauteren et al 2007), Diffeomorphic demons (Vercauteren et al 2007) and MiMVista's deformable registration engine (Pirozzi et al 2013). [4,4;4,4;3,3 The algorithms were evaluated using their vector field differences with the reference field (calculated with the regular Demons algorithm) as shown in figure 10.…”
Section: Registration Evaluationmentioning
confidence: 99%