2017
DOI: 10.1016/j.snb.2017.07.147
|View full text |Cite
|
Sign up to set email alerts
|

A novel flexible electrochemical glucose sensor based on gold nanoparticles/polyaniline arrays/carbon cloth electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
53
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 118 publications
(55 citation statements)
references
References 51 publications
0
53
0
Order By: Relevance
“…The glucose tattoo sensor exhibits a sensitivity of 23 nA/µM and a limit of detection of 3 µM, and a linear response range from 0 to 100 µM. Exploiting two iontophoretic electrodes (anode and cathode) with three amperometric sensing electrodes (working, reference, and counter electrodes) in the anode compartment can also yield a wearable alcohol sensor system (Figure 8d) [46]. By delivering the pilocarpine drug from the anode compartment, iontophoretic electrodes induce the sweat in the anode region for the alcohol analysis with a high sensitivity to detect ethanol (0.362 ± 0.009 µA/mM).…”
Section: Temporary Tattoo-based Biosensorsmentioning
confidence: 99%
See 2 more Smart Citations
“…The glucose tattoo sensor exhibits a sensitivity of 23 nA/µM and a limit of detection of 3 µM, and a linear response range from 0 to 100 µM. Exploiting two iontophoretic electrodes (anode and cathode) with three amperometric sensing electrodes (working, reference, and counter electrodes) in the anode compartment can also yield a wearable alcohol sensor system (Figure 8d) [46]. By delivering the pilocarpine drug from the anode compartment, iontophoretic electrodes induce the sweat in the anode region for the alcohol analysis with a high sensitivity to detect ethanol (0.362 ± 0.009 µA/mM).…”
Section: Temporary Tattoo-based Biosensorsmentioning
confidence: 99%
“…Additionally, not all types of textiles are suitable to integrate sensing materials [38][39][40]. As an alternative, other flexible thin-film substrates (e.g., paper and plastic) have been explored [41][42][43][44][45][46]. However, the intrinsic fracture limit of the flexible thin-film materials is small (e.g., <1% for paper).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In recent work, non-enzymatic glucose sensors with CP-based nanocomposites are becoming new hotspots. Xu et al [315] synthesized a flexible electrochemical sensor based on AuNPs/PANI arrays/CC electrode. The flexible carbon cloth was employed as base electrode, PANI arrays were directly grown on CC electrode, and large number of Au nanoparticles were electrodeposited on the surface.…”
Section: Glucose Sensorsmentioning
confidence: 99%
“…Electroconducting polymers such as polyacetylene, polythiophene, polypyrrole and polyaniline (PAni) have drawn considerable attention because they are promising materials for constructing sensors [1][2][3][4][5], transistors [6,7], supercapacitors [8,9], electrochromic devices [10][11][12], and many other applications. Consequently a lot of researches have been conducted on their preparation, properties and applications [13][14][15].…”
Section: Introductionmentioning
confidence: 99%