2022
DOI: 10.1016/j.ifacol.2022.04.111
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Decentralized FO Voltage and Current Control Scheme for Voltage and Frequency Regulation in Inverter Dominated Islanded Microgrids Using Improved Droop Control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 20 publications
0
5
0
Order By: Relevance
“…Authors in References 28,29 proposes a fuzzy PIDF and cascaded PI‐Fractional order PID controller to optimize the controller gain using marine predator algorithm and Gorilla troops optimizer, respectively. Similar works are reported in References 22–30. In Reference 30 social spider optimization is used to tune the control parameters of the dual area system.…”
Section: Introductionmentioning
confidence: 75%
See 3 more Smart Citations
“…Authors in References 28,29 proposes a fuzzy PIDF and cascaded PI‐Fractional order PID controller to optimize the controller gain using marine predator algorithm and Gorilla troops optimizer, respectively. Similar works are reported in References 22–30. In Reference 30 social spider optimization is used to tune the control parameters of the dual area system.…”
Section: Introductionmentioning
confidence: 75%
“…As such, frequency control of the hybrid microgrid has been explored significantly in the single area. [14][15][16][17][18][19][20][21][22][23][24] The authors in Reference 14 tried to settle the frequency of microgrid that has solar PV, diesel generator and wind turbines as the generating units. The system uses PID controllers optimized with craziness-based particle swarm optimization (CRPSO) optimized PID controller.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…To find the target function, it is necessary to develop a block diagram shown in figure 1, in which, due to feedback from the pressure sensor, we will receive stable pressure in the water supply system [5]. The control system of the autonomous voltage inverter (AIN) will select the parameters of operation, namely, voltage and frequency, thereby reducing the starting and operating currents in the electric drive, which reduce the reliability of the electric drive and directly affect its service life [6][7].…”
Section: Methodsmentioning
confidence: 99%