A Novel Cautery Instrument for On-Site Fenestration of Aortic Stent-Grafts: A Feasibility Study of 18 Patients

Abstract: This simple-to-use instrument makes on-site creation of aortic stent-graft fenestrations easy, accurate, and precise. The instrument is inexpensive, robust, and easily sterilized.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
13
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 23 publications
0
13
0
Order By: Relevance
“…A single fenestration for the LSA of appropriate size and location is made in between the endograft stent struts, in line with the radiopaque figure-8 mid-marker, using a thermal cautery instrument. 4 Thereafter, a radiopaque nitinol wire is sewn onto the edge of the fenestration ( Figure 1A ).…”
Section: Techniquementioning
confidence: 99%
See 1 more Smart Citation
“…A single fenestration for the LSA of appropriate size and location is made in between the endograft stent struts, in line with the radiopaque figure-8 mid-marker, using a thermal cautery instrument. 4 Thereafter, a radiopaque nitinol wire is sewn onto the edge of the fenestration ( Figure 1A ).…”
Section: Techniquementioning
confidence: 99%
“…Endovascular repair is an effective way of treating aortic arch pathology, 1 and fenestrations in the endografts can help preserve flow into supra-aortic branches destined to be covered by the device. 2 5 Precise deployment of these fenestrated arch endografts is important to correctly orient the fenestrations toward the branches for which they are intended. The fenestrations must then be cannulated if covered stents are to be deployed through them into the side branches to achieve a seal at each location.…”
Section: Introductionmentioning
confidence: 99%
“…Three circular fenestrations were made [10-mm diameter for the IA and 8-mm for the LCCA and left subclavian artery (LSA)], and their edges were strengthened with 0.014-inch radiopaque wire sutured on with 5-0 polypropylene. 10 Two radiopaque figure-8 markers were fixed onto the endograft in the 12 o'clock position and brought up to the surface (in contact with the endograft sheath) during resheathing of the endograft ( Figure 6B and C). Orienting these markers toward the outer curvature of the aortic arch during introduction of the endograft delivery system facilitated correct rotational orientation of the fenestrations, which were not prewired, 11 as the arch was not distorted and direct cannulation of the fenestrations seemed feasible.…”
Section: Endograft Preparationmentioning
confidence: 99%
“…The use of fenestrations in the thoracic arch has also become an adjunct for surgeons to place covered stent‐grafts into the subclavian artery in order to extend the proximal landing zone while preserving flow to the left vertebral artery and spinal cord . A thermal cautery instrument was employed to create fenestrations in thoracic stent‐grants that were strengthened using a nitinol wire . There also exist customized thoracic arch fenestrated endografts proposed by Cook for the complete exclusion of all vessels of the arch although these are currently still considered experimental .…”
mentioning
confidence: 99%
“…Based upon previous results of a clinical series , it now seems appropriate to continue to pursue a design for a device that will allow for in situ fenestration of an “off the shelf” endograft . Most of the research to date has focused on the feasibility of the technique . However, the issue of durability has been raised .…”
mentioning
confidence: 99%