A novel and reliable method for tetrahydrobiopterin quantification: Benzoyl chloride derivatization coupled with liquid chromatography-tandem mass spectrometry analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
17
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(18 citation statements)
references
References 32 publications
1
17
0
Order By: Relevance
“…Inaccuracy and imprecision were ≤15% and recovery of BH 4 was 80% when samples were stored for 24 h in the presence of DTE [39]. Alternatively, BH 4 detection upon derivatization with benzoyl chloride coupled with liquid chromatography-tandem mass spectrometry analysis provided a limit of quantification of 0.02 ng/mL (83 pmol/L) in human plasma, and BH 4 levels inversely correlated with age [40]. Other LC/tandem mass spectrometry methods established a limit of quantification of 1 nmol/L for BH 4 and BH 2 and 2.5 nmol/L for biopterin in cultured endothelial cells [57] and of 1 ng/mL (4.2 nmol/L) for BH 4 in human plasma [58].…”
Section: Discussionmentioning
confidence: 99%
“…Inaccuracy and imprecision were ≤15% and recovery of BH 4 was 80% when samples were stored for 24 h in the presence of DTE [39]. Alternatively, BH 4 detection upon derivatization with benzoyl chloride coupled with liquid chromatography-tandem mass spectrometry analysis provided a limit of quantification of 0.02 ng/mL (83 pmol/L) in human plasma, and BH 4 levels inversely correlated with age [40]. Other LC/tandem mass spectrometry methods established a limit of quantification of 1 nmol/L for BH 4 and BH 2 and 2.5 nmol/L for biopterin in cultured endothelial cells [57] and of 1 ng/mL (4.2 nmol/L) for BH 4 in human plasma [58].…”
Section: Discussionmentioning
confidence: 99%
“…Other columns which have also been used for separation include phenyl-hexyl columns [126], AquitiyUPLC HSS T3 columns [124], Partisil-10 SCX columns [130], and Zorbax-Eclipse XDB columns [122]. Also, hydrophilic interaction liquid chromatography (HILIC) can be used, coupled to either MS [119,125] or fluorescence detection [127].…”
Section: Diagnostic Methodsmentioning
confidence: 99%
“…Mass spectrometry is also applied to quantify pterin levels in the samples, as it allows for the specific identification of the compounds. Most protocols use the positive ion-electrospray mode for detection [108,119,124,126], but usage of the negative mode has also been described [105,125].…”
Section: Diagnostic Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Because this was the very first attempt for chemical modification of vitamin D metabolites other than Diels-Alder addiction, we carefully designed and optimized the derivatization process in four aspects: i) Reacting reagent. Recently, benzoyl chloride has been utilized in our laboratory for acylation derivatization (17). However, the absence of an ionizable group made it improper to derivatize vitamin D metabolites.…”
Section: Methods Developmentmentioning
confidence: 99%