A New Measure of Pulse Rate Variability and Detection of Atrial Fibrillation Based on Improved Time Synchronous Averaging

Abstract: Background. Pulse rate variability monitoring and atrial fibrillation detection algorithms have been widely used in wearable devices, but the accuracies of these algorithms are restricted by the signal quality of pulse wave. Time synchronous averaging is a powerful noise reduction method for periodic and approximately periodic signals. It is usually used to extract single-period pulse waveforms, but has nothing to do with pulse rate variability monitoring and atrial fibrillation detection traditionally. If thi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…Depending on the type of device used, three categories can be distinguished, namely, wristband devices, belts, and others. For example, in [ 45 , 47 , 55 , 68 , 70 , 80 , 85 , 98 , 103 , 107 , 108 , 112 ], the authors used smartwatches and smart wristbands to record vital signs. In addition, the authors in [ 40 , 44 , 49 , 63 , 64 , 76 , 78 , 83 , 91 , 93 , 96 , 102 , 110 , 120 , 121 ] used various wearable ECG devices such as smart vests and patches.…”
Section: Resultsmentioning
confidence: 99%
“…Depending on the type of device used, three categories can be distinguished, namely, wristband devices, belts, and others. For example, in [ 45 , 47 , 55 , 68 , 70 , 80 , 85 , 98 , 103 , 107 , 108 , 112 ], the authors used smartwatches and smart wristbands to record vital signs. In addition, the authors in [ 40 , 44 , 49 , 63 , 64 , 76 , 78 , 83 , 91 , 93 , 96 , 102 , 110 , 120 , 121 ] used various wearable ECG devices such as smart vests and patches.…”
Section: Resultsmentioning
confidence: 99%
“… Both matrices of steps 4 and 5 were concatenated together and saved in CSV format for training and testing the network. As each cardiac cycle interval was considered to be 0.6 s to 1 s, the signals were segmented into the cardiac cycle with a length of 1 s as one beat [ 13 ]. …”
Section: Methodsmentioning
confidence: 99%
“…As each cardiac cycle interval was considered to be 0.6 s to 1 s, the signals were segmented into the cardiac cycle with a length of 1 s as one beat [ 13 ].…”
Section: Methodsmentioning
confidence: 99%
“…Electrical, fluid dynamic and mechanical noise were reduced by collecting data in 50 wave sets and analyzing the time synchronous ensemble average 55 of the individual pressure waves ( Supplemental Figure 4 ), inlet flows and pulse valve positions. All signals were sampled at 10 ksps and the data acquisition system (DT9826, Measurement Computing Corporation, USA) received a synchronizing signal from the pulse engine.…”
Section: Methodsmentioning
confidence: 99%
“…Design G pulse profile 2 wave behavior was characterized with sequential data obtained by positioning the pressure sensors at the phantom long axis midpoint then retracting by 5 mm increments until sensors were 5 mm from each phantom end. Electrical, fluid dynamic and mechanical noise were reduced by collecting data in 50 wave sets and analyzing the time synchronous ensemble average 55 of the individual pressure waves (Supplemental Figure 4), inlet flows and pulse valve positions. All signals were sampled at 10 ksps and the data acquisition system (DT9826, Measurement Computing Corporation, USA) received a synchronizing signal from the pulse engine.…”
Section: Pulsatile Behaviormentioning
confidence: 99%