2017
DOI: 10.1109/tpel.2016.2531379
|View full text |Cite
|
Sign up to set email alerts
|

A Multifunctional and Wireless Droop Control for Distributed Energy Storage Units in Islanded AC Microgrid Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
68
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 84 publications
(68 citation statements)
references
References 36 publications
0
68
0
Order By: Relevance
“…Although the rank of coefficient matrix E−M is n (rank (E−M) < n + 1), the solution space of (19) is still definite for an initial condition f * (0) = 50 − mQ * (i.e., special solution). The CFR calculation is similar to an iteration process of (14) with the initial value: 50 − mQ * . Due to the uncertainty of load changes, it is preferential to obtain the frequency reference at the current running moment.…”
Section: Of 18mentioning
confidence: 99%
See 2 more Smart Citations
“…Although the rank of coefficient matrix E−M is n (rank (E−M) < n + 1), the solution space of (19) is still definite for an initial condition f * (0) = 50 − mQ * (i.e., special solution). The CFR calculation is similar to an iteration process of (14) with the initial value: 50 − mQ * . Due to the uncertainty of load changes, it is preferential to obtain the frequency reference at the current running moment.…”
Section: Of 18mentioning
confidence: 99%
“…Due to the uncertainty of load changes, it is preferential to obtain the frequency reference at the current running moment. Even in case of continuous or frequent load variations, the proposed CFR calculation at all load change moments is feasible, otherwise, use (14) directly to calculate the frequency reference at the current running moment. …”
Section: Of 18mentioning
confidence: 99%
See 1 more Smart Citation
“…In essence, the 'modified global indicator' concept has been demonstrated to be effective for improving reactive power sharing in ac MGs, but only in typical structure with common bus [13,14]. In this paper, we extend the application of such global indicator concept to dc MGs with multiple buses.…”
Section: Introductionmentioning
confidence: 99%
“…A small power system consisting of power converter-based generation, ES devices, small classic synchronous generation, and various types of loads forms a microgrid (MG) [4]. While a number of research works on MG have been done on various aspects, including control strategy [5][6][7][8][9][10], energy management systems [11][12][13][14][15][16][17], marketing policies [18][19][20][21] and system design [22][23][24][25][26][27], this paper mainly focuses on the optimal sizing of Distributed Energy Resources (DERs), especially the capacity of ES devices in MG.…”
Section: Introductionmentioning
confidence: 99%