2016
DOI: 10.1016/j.energy.2015.11.044
|View full text |Cite
|
Sign up to set email alerts
|

A multi-criterion renewable energy system design optimization for net zero energy buildings under uncertainties

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
77
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 146 publications
(77 citation statements)
references
References 26 publications
0
77
0
Order By: Relevance
“…validated by the developers (e.g., Type 666 for the chiller, Type 742 for the constant speed pump in the primary chilled water loop, Type 741 for the variable speed pump in the secondary chilled water loop, Type 744 for the ventilation fan), which are the same as those in previous studies[12,[67][68][69][70][71][72]. The energy consumption of the chiller is calculated from Equations 8-12, and the energy consumptions of the pumps and fans are estimated using Equations 13 and 14 respectively[71][72][73]. The key air conditioning system in TRNSYS are summarized inTable 2, more detailed descriptions of the energy consumption evaluation of the air conditioning system are available in studies[67][68][69][70][71][72].…”
mentioning
confidence: 90%
See 1 more Smart Citation
“…validated by the developers (e.g., Type 666 for the chiller, Type 742 for the constant speed pump in the primary chilled water loop, Type 741 for the variable speed pump in the secondary chilled water loop, Type 744 for the ventilation fan), which are the same as those in previous studies[12,[67][68][69][70][71][72]. The energy consumption of the chiller is calculated from Equations 8-12, and the energy consumptions of the pumps and fans are estimated using Equations 13 and 14 respectively[71][72][73]. The key air conditioning system in TRNSYS are summarized inTable 2, more detailed descriptions of the energy consumption evaluation of the air conditioning system are available in studies[67][68][69][70][71][72].…”
mentioning
confidence: 90%
“…The energy consumption of the chiller is calculated from Equations 8-12, and the energy consumptions of the pumps and fans are estimated using Equations 13 and 14 respectively[71][72][73]. The key air conditioning system in TRNSYS are summarized inTable 2, more detailed descriptions of the energy consumption evaluation of the air conditioning system are available in studies[67][68][69][70][71][72].…”
mentioning
confidence: 99%
“…However, this could increase the cost and system complexity of the ventilation system. The design of the ventilation system should balance the capability to satisfy differentiated thermal preferences and the increased cost and system complexity, e.g., using the multi-criteria decision-making method [48].…”
Section: Discussionmentioning
confidence: 99%
“…weighting factors [48] to prioritize the thermal comforts of the occupants concerned particularly. This study only presents the PMVs of the subzones at the height of 1.1 m which are adequate for the evaluation of thermal comfort under stratum ventilation, and more detailed information about the microclimates of stratum ventilation can be found in Studies [15,32].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation