2013
DOI: 10.2478/mms-2013-0025
|View full text |Cite
|
Sign up to set email alerts
|

A Multi-Band Integrated Virtual Calibration-Inversion Method for Open Path FTIR Spectrometry

Abstract: This paper addresses problems arising from in situ measurement of gas content and temperature. Such measurements can be considered indirect. Transmittance or natural radiation of a gas is measured directly. The latter method (spectral radiation measurement) is often called spectral remote sensing. Its primary uses are in astronomy and in the measurement of atmospheric composition. In industrial processes, in situ spectroscopic measurements in the plant are often made with an open path Fourier Transform Infrare… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 24 publications
0
6
0
Order By: Relevance
“…In many problems the temperature has significant influence on the analyzed transmission spectra. In some works a synthetic calibration due to the temperature impact is performed, especially in spectroscopy [22,23]. For the purposes of this work no temperature and strain changes have been assumed.…”
Section: Bistable System Mathematical Modelmentioning
confidence: 99%
“…In many problems the temperature has significant influence on the analyzed transmission spectra. In some works a synthetic calibration due to the temperature impact is performed, especially in spectroscopy [22,23]. For the purposes of this work no temperature and strain changes have been assumed.…”
Section: Bistable System Mathematical Modelmentioning
confidence: 99%
“…As a scattering phase function of the tissue, use was made of the Henyey -Greenstein function with the parameter g(λ). Modeling and approximation of spectral features is a commonly applied approach of data analysis in different kind of spectroscopic methods [9][10].…”
Section: Analytical Calculation Of Diffuse Reflectance Characteristicmentioning
confidence: 99%
“…ILS shape additionally depends on spectrometer field of view and inaccuracies of spectrometer optics construction. Because of accurate ILS modeling is difficult, the equivalent width [26] and the band integrated method [27] were created which are independent from apparatus function of the spectrometer.…”
Section: Temperature Problem In Spectrometric Measurementmentioning