1996
DOI: 10.1016/0043-1648(96)06929-3
|View full text |Cite
|
Sign up to set email alerts
|

A machine for fretting fatigue and fretting wear testing in cryotechnical and normal environment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

1999
1999
2015
2015

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 2 publications
0
16
0
Order By: Relevance
“…The new fretting tribometer (Vibro Thermo Tribometer -VTTM) is designed as an ambient and high temperature evolution of a cryotechnical environment fretting test rig (Vibro Cryo TriboMeter -VCTM) already in use at LISMMA laboratory [11]. It is based on the same principle, but optimized in order to increase the frequency, displacement amplitude and normal load operating range.…”
Section: Test Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…The new fretting tribometer (Vibro Thermo Tribometer -VTTM) is designed as an ambient and high temperature evolution of a cryotechnical environment fretting test rig (Vibro Cryo TriboMeter -VCTM) already in use at LISMMA laboratory [11]. It is based on the same principle, but optimized in order to increase the frequency, displacement amplitude and normal load operating range.…”
Section: Test Setupmentioning
confidence: 99%
“…Contact measurement methods generally involve LVDT (Linear Variable Differential Transformer) sensors [12,13]. Contactless methods regroup Eddy current sensors [11] and optical methods: digital image correlation [12], LDV (Laser Doppler Vibrometers) [9,14] and photonic optic fibres sensors [15]. Eddy current sensors require a specific target with size constraints, and compatible material requirements.…”
Section: Displacement Measurementmentioning
confidence: 99%
“…To measure the tangential force, in addition to the force sensor (12) attached to the longitudinal actuator (13), the fixed head (21) of the machine is equipped with a force sensor (20). The tangential force Q is calculated from efforts F 1 and F 2 measured by sensors (12) and (20), hence:…”
Section: Fretting-fatigue Configurationmentioning
confidence: 99%
“…The V.C.T.M. apparatus is described in more detail elsewhere 18. Fretting‐wear tests were conducted at 50 Hz under a mean pressure of 588 MPa with a displacement of ±32 µm.…”
Section: Experimental Partmentioning